{"product_id":"belaire-338ve-air-compressor","title":"BelAire Air Compressor 338VE Elite Series 5 HP 80 Gallon Two Stage","description":"\u003ch2\u003eBelAire 338VE Elite Series 5 HP 80-Gallon Two-Stage Air Compressor, Vertical 3-Phase\u003c\/h2\u003e \u003cp\u003eStainless steel valves. It is a single line on a specification sheet and it is the most consequential thing on this one, because valves are the highest-duty parts in any reciprocating compressor and they are what usually decides when the pump has had enough. The 338VE specifies them in stainless, pairs them with a solid cast iron pump and a triple-pass pump-mounted aftercooler, and stands the whole thing on an 80-gallon vertical tank that BelAire states is 100% factory tested at full pressure.\u003c\/p\u003e \u003cp\u003eIt runs on 208-230V 3-phase supply with a 5 HP motor and a magnetic starter already fitted, and it delivers 16.6 CFM at 175 PSI, which is also its maximum pressure.\u003c\/p\u003e \u003ch3\u003eWhy the valves decide how long the pump lives\u003c\/h3\u003e \u003cp\u003eCount the duty cycle of a compressor valve and the number stops being abstract. Every piston stroke opens and closes it. A pump running through a working day accumulates cycles into the millions in a season, and it does so in the harshest environment inside the machine: hot discharge air, oil mist, and the moisture that compression keeps squeezing out of the atmosphere.\u003c\/p\u003e \u003cp\u003eTwo things end a valve. Fatigue, from being flexed relentlessly, and corrosion, from sitting in warm, wet, oily air between runs. Stainless steel is specified for the second problem in particular — it does not pit and scale the way ordinary steel does in condensing air, and a pitted valve does not seal, which shows up first as lost output and rising discharge temperature rather than as an obvious failure.\u003c\/p\u003e \u003cp\u003eThe practical effect for an owner is that the machine holds its output as it ages instead of quietly getting weaker. A compressor that has lost a fifth of its delivery to worn valves will still run, still build pressure eventually, and still feel roughly normal — which is exactly why the loss goes unnoticed until somebody measures it.\u003c\/p\u003e \u003ch3\u003eTwo stages, and the cooling in between\u003c\/h3\u003e \u003cp\u003eSingle-stage pumps squeeze the air once. Two-stage pumps squeeze it in a large cylinder, cool it, then squeeze it again in a small high-pressure cylinder. The intercooling between the stages is the point: cooler air is denser, denser air takes less work to compress further, and the second stage does its job without the discharge temperature climbing to where oil breaks down and valves suffer.\u003c\/p\u003e \u003cp\u003eThe triple-pass aftercooler then handles the air on its way out to the receiver, dropping its temperature so a good share of the moisture condenses at the machine rather than in your pipework. Together, intercooling and aftercooling are why a two-stage compressor of this size runs cooler and lasts longer than a single-stage machine of the same nominal power — and why the valves, the oil and the bearings all get an easier life.\u003c\/p\u003e \u003ch3\u003eVertical, three phase, and where it goes\u003c\/h3\u003e \u003cp\u003eThe receiver stands upright, so the machine occupies about 39\" by 24\" of floor and stands 77\" tall, weighing 453 lbs. Height is the dimension to check before you order: measure your ceiling, any door header on the route in, and any duct or beam over the intended spot, and leave clearance above for the outlet fitting and its piping elbow. If it is close, ask us to confirm the height in writing first. Stand it on a level, solid floor; a tall machine on an uneven slab works its own mountings.\u003c\/p\u003e \u003cp\u003eThe supply is 208-230V 3-phase and BelAire recommends a 30 amp breaker. Actual amp draw is listed as something to confirm with a certified electrician rather than published as one number, because it depends on your service, your run length and your local code — and having it checked before delivery is the customer's responsibility. The magnetic starter is included and factory fitted, giving proper motor overload protection out of the crate. Check the flywheel turns with the arrow on the guard at first start: three-phase rotation follows the conductor order, and a backwards pump makes noise and no useful air.\u003c\/p\u003e \u003ch3\u003eConfirm whether the tank drain is automatic\u003c\/h3\u003e \u003cp\u003ePublished descriptions of the tank drain differ. The manufacturer's feature list for this model describes an Elite Series automatic tank drain, expressly not electronic. The product overview text supplied with the same model describes a manual tank drain valve. The specification data records no electronic drain valve, which is consistent with either.\u003c\/p\u003e \u003cp\u003eAutomatic and manual are not variations on a theme — one empties the condensate for you, the other requires you to do it at the end of every working day, and undrained water is what destroys receivers from the inside. \u003cstrong\u003eIf automatic draining is a requirement rather than a nice-to-have for your installation, ask us to confirm it in writing before you order\u003c\/strong\u003e, and until then plan on draining it yourself.\u003c\/p\u003e \u003ch3\u003eAsk us for the 100 PSI airflow figure before you size a tool list\u003c\/h3\u003e \u003cp\u003eThe delivered air at 175 PSI is not in doubt and is published above. Published figures for delivery at 100 PSI differ by a small but real amount, so that row is left for confirmation rather than carrying one of them. \u003cstrong\u003eIf you are sizing a tool list against it, ask us and we will get the figure in writing from the manufacturer before you commit.\u003c\/strong\u003e\u003c\/p\u003e \u003ch3\u003ePerfect For\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eCommercial shops with three-phase service\u003c\/strong\u003e that want longevity rather than the largest headline output.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eOperations running the compressor hard and continuously\u003c\/strong\u003e, where valve life is a genuine running cost.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBuildings short on floor area\u003c\/strong\u003e but with the headroom for a vertical tank.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePaint, body and finishing work\u003c\/strong\u003e that benefits from aftercooled air reaching the drying and filtration stack.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eIn the box\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eTwo-stage pump, solid cast iron\u003c\/li\u003e \u003cli\u003eStainless steel valves\u003c\/li\u003e \u003cli\u003eTriple-pass pump-mounted aftercooler\u003c\/li\u003e \u003cli\u003e80-gallon ASME certified vertical air tank, 100% factory tested at full pressure\u003c\/li\u003e \u003cli\u003e5 HP three-phase motor with magnetic starter included\u003c\/li\u003e \u003cli\u003eStart-stop pressure switch control\u003c\/li\u003e \u003cli\u003eLow oil switch and oil level sight glass\u003c\/li\u003e \u003cli\u003eFully enclosed high-flow belt guard\u003c\/li\u003e \u003cli\u003ePressure gauge\u003c\/li\u003e \u003cli\u003eTank drain — see the contradiction note above regarding its type\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eNot included: an air dryer.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ch4\u003ePump and air\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePump\u003c\/th\u003e \u003ctd\u003eTwo-stage, belt drive, solid cast iron\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eValves\u003c\/th\u003e \u003ctd\u003eStainless steel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAftercooler\u003c\/th\u003e \u003ctd\u003eTriple-pass, pump mounted\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDelivered air at 175 PSI\u003c\/th\u003e \u003ctd\u003e16.6 CFM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDelivered air at 100 PSI\u003c\/th\u003e \u003ctd\u003eConfirm with us — published figures differ. See the note above.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eLubrication\u003c\/th\u003e \u003ctd\u003eOil lubricated, splash system, sight glass and low oil switch\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003eMotor and supply\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e \u003ctd\u003e5 HP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e \u003ctd\u003e208-230V, 3-phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eRecommended breaker\u003c\/th\u003e \u003ctd\u003e30 amp\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAmp draw\u003c\/th\u003e \u003ctd\u003eConfirm with a certified electrician\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e \u003ctd\u003eMagnetic starter included\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003eTank and dimensions\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e \u003ctd\u003e80-gallon, vertical, ASME certified, 100% factory tested at full pressure\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e \u003ctd\u003e3\/4\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eFootprint\u003c\/th\u003e \u003ctd\u003e39\" by 24\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e \u003ctd\u003e77\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e453 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch3\u003eCertification, plainly\u003c\/h3\u003e \u003cp\u003eThe receiver is an ASME certified pressure vessel and BelAire states it is tested at full pressure at the factory. Those claims are real, they are checkable, and they concern the tank.\u003c\/p\u003e \u003cp\u003eWe do not hold a North American third-party electrical safety listing issued by an accredited testing laboratory for this compressor. That is a separate assessment of the motor, the starter and the control wiring, and a pressure vessel certification tells you nothing about any of them. Certain insurers, corporate facility standards and local electrical inspectors require that listing specifically. If yours might, settle the question and ask us in writing before you order rather than after the machine is standing in your building.\u003c\/p\u003e \u003ch3\u003eDelivery\u003c\/h3\u003e \u003cp\u003eThis item ships free within the lower 48 states, so there is nothing to add at checkout.\u003c\/p\u003e \u003cp\u003eArrange the unload in advance: a forklift or a dock at the delivery address, or take terminal pickup and collect it yourself. Residential delivery is available and carries a residential fee. Because this one travels upright, inspect for lean and tipping as well as the usual dents in the tank ends, distortion in the belt guard and oil on the trailer deck. Record whatever you find on the delivery paperwork and photograph it while the driver is still on site, then sign. Damage raised after a clean signature is extremely hard to recover.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eA 2-year full factory warranty applies. Take the serial number down as soon as the machine is uncrated and keep it filed with the invoice.\u003c\/p\u003e \u003cp\u003eDo not take the pump, motor or pressure switch apart before a claim is opened — dismantling a component to prove it failed is the most reliable way to lose the cover on that component. Report it first. Beyond that, keep to the manufacturer's oil interval, re-check belt tension after the first weeks of running, and drain the receiver at the end of the working day while there is still pressure behind the water.\u003c\/p\u003e","brand":"BelAire Compressors","offers":[{"title":"Default Title","offer_id":49287154204826,"sku":"338VE","price":2361.1,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/belaire-338ve-air-compressor","provider":"My Store","version":"1.0","type":"link"}