{"product_id":"chicago-pneumatic-rcp-c581v-air-compressor","title":"Chicago Pneumatic Air Compressor RCP-C581V 5 HP 80 Gallon Two Stage Cast Iron 208-230V 1 Phase","description":"\u003ch2\u003eChicago Pneumatic RCP-C581V: a two-year warranty that includes the valves\u003c\/h2\u003e \u003cp\u003eRead enough compressor warranties and you learn where the fine print lives. Valves are usually the first exclusion — they are the part that wears, the part carbon and heat attack, and the part a manufacturer least wants to replace. This machine is sold with a \u003cstrong\u003e2 Year\u003c\/strong\u003e full warranty that this product's own listing states covers everything on the unit \u003cem\u003eincluding valves\u003c\/em\u003e, with nothing extra to purchase to hold it. That is a different proposition from an extended plan you buy separately and then have to qualify for.\u003c\/p\u003e \u003cp\u003eThe machine that cover applies to is a \u003cstrong\u003e5 HP\u003c\/strong\u003e two-stage compressor with a solid cast iron pump, on an \u003cstrong\u003e80 Gallon ASME\/CRN\u003c\/strong\u003e vertical tank, rated \u003cstrong\u003e18 CFM @ 100 psi\u003c\/strong\u003e and \u003cstrong\u003e175 psi\u003c\/strong\u003e maximum, running on \u003cstrong\u003e208-230 Volt\u003c\/strong\u003e single-phase supply. It is aimed squarely at a two- or three-person automotive shop, or one person doing light body work.\u003c\/p\u003e  \u003ch2\u003eTwo-stage, and why it matters at 175 psi\u003c\/h2\u003e \u003cp\u003eA single-stage pump compresses air once and hands it to the tank. A two-stage pump compresses it, cools it between stages, then compresses it again. That intercooling is the whole reason a machine like this holds \u003cstrong\u003e175 psi\u003c\/strong\u003e as a working condition rather than as a strained maximum it reaches on a cold morning and never repeats.\u003c\/p\u003e \u003cp\u003eHigher available pressure is useful in two ways that show up daily. It gives you headroom, so the regulator at the tool sees a steady supply rather than the tail end of a falling tank. And it means more stored energy for the same \u003cstrong\u003e80 Gallon\u003c\/strong\u003e of tank volume, which is what carries you through a burst of demand — an impact gun on a stubborn hub, three wheels off in quick succession — without the pump running continuously to keep up.\u003c\/p\u003e \u003cp\u003eThe pump itself is solid cast iron. Cast iron is heavy, and that is the point: mass absorbs and sheds the heat of compression instead of letting it build in the pump, and a cast iron cylinder wears slowly and can be worked on rather than replaced as an assembly. Chicago Pneumatic's Iron Series is built around low pump speed and heavy construction for exactly that reason — long life and comparatively quiet running.\u003c\/p\u003e  \u003ch2\u003eWhy the vertical tank decides where it goes\u003c\/h2\u003e \u003cp\u003eThis is the vertical-tank configuration, and that choice is about floor space rather than performance. An \u003cstrong\u003e80 Gallon\u003c\/strong\u003e vertical receiver stands the storage on end, so the machine occupies a corner instead of a wall. In a two-bay shop where every square foot is either a working bay or a walkway, that is often the difference between the compressor fitting and the compressor being a problem.\u003c\/p\u003e \u003cp\u003eThe trade is height and headroom. A vertical machine needs ceiling clearance above the tank and a genuinely level floor beneath it, because everything above is standing on the tank feet. Bolt it down on a flat, solid pad — \u003cstrong\u003e590 lbs\u003c\/strong\u003e standing tall is not something to leave sitting on a rocking corner.\u003c\/p\u003e  \u003ch2\u003eWill It Fit? Power, floor and services\u003c\/h2\u003e \u003cp\u003eChecking the supply, floor and clearances before ordering is the buyer's responsibility. Take the electrical line to an electrician early; the rest you can measure yourself.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eElectrical supply:\u003c\/strong\u003e \u003cstrong\u003e208-230 Volt\u003c\/strong\u003e, \u003cstrong\u003e1 Phase\u003c\/strong\u003e, with a magnetic starter fitted. A five-horsepower single-phase motor is a substantial circuit — confirm your panel has the capacity before the machine is on a truck, not after. Conductor size and breaker rating depend on the run length and local code, and are your electrician's decision.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eTank:\u003c\/strong\u003e \u003cstrong\u003e80 Gallon ASME\/CRN\u003c\/strong\u003e, vertical, with safety valves.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFootprint:\u003c\/strong\u003e our data records an overall length of \u003cstrong\u003e37\"\u003c\/strong\u003e. Overall width and height are stored without units, so we have not printed them — a bare number is not a measurement, and on a vertical machine the height is the figure you least want to guess. Ask us and we will confirm the dimensioned drawing before you clear a space.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cstrong\u003e590 lbs\u003c\/strong\u003e, concentrated on the tank feet. Level and solid, or the mounts work loose.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eTank outlet:\u003c\/strong\u003e \u003cstrong\u003e3\/4\"\u003c\/strong\u003e. Size your shop main from that connection rather than from your old machine's.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eVentilation:\u003c\/strong\u003e an air-cooled pump needs moving air around it. A compressor shut in an unventilated cupboard runs hot and ages fast.\u003c\/li\u003e \u003c\/ul\u003e  \u003ch2\u003ePerfect For\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eTwo- and three-person automotive shops\u003c\/strong\u003e — the application this product's own description names.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eOne-person light body work\u003c\/strong\u003e, where air runs for long spells rather than in short bursts.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSingle-phase buildings\u003c\/strong\u003e with a panel that can carry a 5 HP motor circuit.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eShops short of floor space\u003c\/strong\u003e and long on ceiling height.\u003c\/li\u003e \u003c\/ul\u003e  \u003ch2\u003eWhat's in the Box\u003c\/h2\u003e \u003cp\u003eThe compressor as a complete assembly: the two-stage solid cast iron pump and motor mounted on the \u003cstrong\u003e80 Gallon ASME\/CRN\u003c\/strong\u003e vertical tank, with its magnetic starter, gauges, tank drain and safety valves.\u003c\/p\u003e \u003cp\u003eNot supplied: the electrical installation and its circuit, any air dryer or downstream filtration, and shop pipework from the \u003cstrong\u003e3\/4\"\u003c\/strong\u003e outlet. This machine is not specified with an air dryer or an electronic drain valve, so if you spray or run air-driven instrumentation, budget for drying separately. If your order depends on an item being included, ask us to confirm it in writing before you buy.\u003c\/p\u003e  \u003ch2\u003eSpecifications\u003c\/h2\u003e \u003ctable\u003e \u003cthead\u003e\u003ctr\u003e \u003cth scope=\"col\"\u003eOutput and pressure\u003c\/th\u003e \u003cth scope=\"col\"\u003e\u003c\/th\u003e \u003c\/tr\u003e\u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eRated flow\u003c\/th\u003e \u003ctd\u003e18 CFM @ 100 psi\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 psi\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eStages\u003c\/th\u003e \u003ctd\u003eTwo stage, with intercooling between stages\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003cthead\u003e\u003ctr\u003e \u003cth scope=\"col\"\u003eMotor, pump and supply\u003c\/th\u003e \u003cth scope=\"col\"\u003e\u003c\/th\u003e \u003c\/tr\u003e\u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e \u003ctd\u003e5 HP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePump\u003c\/th\u003e \u003ctd\u003eSolid cast iron\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e \u003ctd\u003e208-230 Volt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e \u003ctd\u003e1 Phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMagnetic starter\u003c\/th\u003e \u003ctd\u003eFitted\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003cthead\u003e\u003ctr\u003e \u003cth scope=\"col\"\u003eTank, size and weight\u003c\/th\u003e \u003cth scope=\"col\"\u003e\u003c\/th\u003e \u003c\/tr\u003e\u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e \u003ctd\u003e80 Gallon, vertical, ASME\/CRN\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e \u003ctd\u003e3\/4\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOverall length\u003c\/th\u003e \u003ctd\u003e37\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e590 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAir dryer\u003c\/th\u003e \u003ctd\u003eNot fitted\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eElectronic drain valve\u003c\/th\u003e \u003ctd\u003eNot fitted\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003eWith no electronic drain, condensate comes out of the tank by hand. On a vertical receiver that drain is at the bottom of a tall column of water, so it is worth doing weekly and worth fitting an accessible drain line if the tank is tucked into a corner.\u003c\/p\u003e  \u003ch2\u003eCertification, stated plainly\u003c\/h2\u003e \u003cp\u003eThe claim this product's data makes is about the receiver: an \u003cstrong\u003eASME\/CRN\u003c\/strong\u003e tank with safety valves. That is the pressure-vessel side of the machine and it is the claim that carries most weight on a tank working at \u003cstrong\u003e175 psi\u003c\/strong\u003e.\u003c\/p\u003e \u003cp\u003eWhat the data does not claim is a third-party safety listing for the packaged machine, and we are not going to imply one. A receiver certification is a statement about the receiver, not about the motor, the starter or the assembly. Installation to local electrical code is your electrician's responsibility, and where a jurisdiction inspects pressure vessels, that requirement still applies once the tank is in your building. If your insurer or facility standard asks for specific documentation, tell us before you order and we will establish what this model can evidence, in writing.\u003c\/p\u003e  \u003ch2\u003eShipping and delivery\u003c\/h2\u003e \u003cp\u003eThe compressor ships as palletised freight within the lower 48 states, free of charge.\u003c\/p\u003e \u003cp\u003eArrange the unload before you order — this is the part people leave to the day. \u003cstrong\u003e590 lbs\u003c\/strong\u003e standing on a pallet needs a forklift, a dock, or a pallet jack with level ground; the driver's responsibility ends at the back of the trailer. If you have none of that, choose terminal pickup and collect it with your own transport. A home address is a residential delivery and carries a residential fee.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eInspect it before you sign.\u003c\/strong\u003e Look over the tank, the pump, the gauges and the fittings while the driver is still there, and write any damage or shortage onto the bill of lading before signing. A tall vertical tank is exactly the kind of freight that gets knocked in transit, and a note on the paperwork is what turns that into a claim rather than an argument.\u003c\/p\u003e  \u003ch2\u003eWarranty\u003c\/h2\u003e \u003cp\u003eThe \u003cstrong\u003e2 Year\u003c\/strong\u003e full warranty described above is the headline here, and it is worth restating precisely: this product's listing says it covers everything on the machine, valves included, with nothing to purchase to activate it.\u003c\/p\u003e \u003cp\u003eOne rule of ours protects that cover. If the pump develops a fault, leave it assembled and call us. Once it has been stripped, nobody can establish what failed first — and a claim on a dismantled pump becomes a conversation about opinion rather than evidence. Photograph what you can see, stop using the machine, and let it be assessed whole.\u003c\/p\u003e","brand":"Chicago Pneumatic","offers":[{"title":"Default Title","offer_id":49287160103066,"sku":"RCP-C581V","price":2993.2,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/chicago-pneumatic-rcp-c581v-air-compressor","provider":"My Store","version":"1.0","type":"link"}