Description
Description:
Features:
- 200MHz bandwidths
- 1GSa/s Real Time sample rate
- Large (7.0-inch) color display,WVGA(800x480)
- Record length up to 40K
- Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
- USB host and device connectivity, standard
- Multiple automatic measurements
- Four math functions, including FFTs standard
- Provides software for PC real-time analysis
- VGA Optional
Specifications:
| Model | DSO5202P |
| Acquisition | |
| Sample Rate | Real-Time Sample: 1GS/s |
| Acquisition Modes |
|
| Normal | Normal data only |
| Peak Detect | High-frequency and randon glith capture |
| Average | Wavefom Average, selectable 4,8,16,32,64,128 |
| Inputs | |
| Inputs Coupling | AC, DC, GND |
| Inputs Impendance | 1MΩ±2% ?20pF±3pF |
| Probe Attenuation | 1X, 10X |
| Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X |
| Maximum Input Voltage | CAT I and CAT II: 300VRMS (10×), Installation Category; |
| Horizontal System | |
| Sample Rate Range | 500MS/s--1GS/s |
| Waveform Interpolation | (sin x)/x |
| Record Length | 40K |
| SEC/DIV Range | 2ns/div to 40s/div |
| Sample Rate and | ±50ppm(at over any â‰?ms time interval) |
| Position Range | 2ns/div to 10ns/div; (-4div x s/div) to 20ms; |
| Delta Time Measurement Accuracy | Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); |
| Vertical System | |
| Vertical Resolution | 8-bit resolution, all channel sampled simultaneously |
| Position Range | 2mV/div to 10V/div |
| Bandwidth | 200MHz |
| Rise Time at BNC( typical) | 1.8ns |
| Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled | 2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V |
| Math | +, -, *, /, FFT |
| FFT | Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; |
| Bandwidth Limit | 20MHz |
| Low Frequency Response (-3db) | �0Hz at BNC |
| DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; |
| DC Measurement Accuracy, | When vertical displacement is zero, and N â‰?6:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; |
| Volts Measurement Repeatability, | Delta volts between any two averages of �6 waveforms acquired under same setup and ambient conditions |
| Trigger System | |
| Trigger Types | Edge, Video, Pulse, Slope, Over time, Alternative |
| Trigger Source | CH1, CH2, EXT, EXT/5, AC Line |
| Trigger Modes | Auto, Normal, Single |
| Coupling Type | DC, AC, Noise Reject, HF Reject, LF Reject |
| Trigger Sensitivity | DC(CH1,CH2): |
| Trigger Level Range | CH1/CH2: ±8 divisions from center of screen; |
| Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times â‰?0ns | CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; |
| Set Level to 50%(typical) | Operates with input signals �0Hz |
| Video Trigger |
|
| Video Trigger Type | CH1, CH2: Peak-to-peak amplitude of 2 divisions; |
| Signal Formats and Field Rates, Video Trigger Type | Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
| Holdoff Range | 100ns ~ 10s |
| Pulse Width Trigger |
|
| Pulse Width Trigger Mode | Trigger when (< , >, = , or �; Positive pulse or Negative pulse |
| Pulse Width Trigger Point | Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. |
| Pulse Width Range | 20ns ~ 10s |
| Slope Trigger |
|
| Slope Trigger Mode | Trigger when (< , > , = , or �); Positive slope or Negative slope |
| Slope Trigger Point | Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. |
| Time Range | 20ns ~ 10s |
| Overtime Trigger |
|
| Over Time Mode | Rising edge or Falling edge |
| Time Range | 20ns ~ 10s |
| Alternative Trigger |
|
| Trigger on CH1 | Internal Trigger: Edge, Pulse Width, Video, Slope |
| Trigger on CH2 | Internal Trigger: Edge, Pulse Width, Video, Slope |
| Trigger Frequency Counter | |
| Readout Resolution | 6 digits |
| Accuracy (typical) | ±30ppm (including all frequency reference errors and ±1 count errors) |
| Frequency Range | AC coupled, from 4Hz minimum to rated bandwidth |
| Signal Source | Pulse Width or Edge Trigger modes: all available trigger sources |
| Measure | |
| Cursor Measurement | Voltage difference between cursors: ?V |
| Auto Measuerment | Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF |
| Display | |
| Display Type | 7 inch 64K color TFT (diagonal liquid crystal) |
| Display Resolution | 800 horizontal by 480 vertical pixels |
| Display Contrast | Adjustable (16 gears) with the progress bar |
| Probe Compensator Output | |
| Output Voltage( typical) | About 5Vpp into â‰?MΩ load |
| Frequency(typical) | 1kHz |
| Power Supply | |
| Supply Voltage | 100-120VACRMS(±10%), 45Hz to 440Hz, CAT? |
| Power Consumption | <30W |
| Fuse | 2A, T rating, 250V |
| Environmental | |
| Temperature | Operating: 32? to 122? (0? to 50?); |
| Cooling Method | Convection |
| Humidity | +104? or below (+40? or below): �0% relative humidity; |
| Altitude | Operating: Below 3,000m (10,000 feet); |
| Mechanical | |
| Size | Length 385mm, Width 200mm, Height 245mm |
| Weight | 3.5KG(with Packing); 2.08KG(without Packing) |
Package List:
- 1xDigital storage Oscilloscope
- 1xOscilloscope Probe Kit two sets
- 1xOscilloscope powerline
- 1xHantek data CD & Warranty Card customer return receipt & Manufacturer certificate
- 1xUSB line
Return policy
Our goal is for every customer to be totally satisfied with their purchase. If this isn't the case, let us know and we'll do our best to work with you to make it right.
Shipping
We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.
Manufacturing
Our products are manufactured both locally and globally. We carefully select our manufacturing partners to ensure our products are high quality and a fair value.