{"product_id":"lanair-xt200-waste-oil-heater-value-package-3","title":"LANAIR XT200 Waste Oil Heater Value Package 3","description":"\u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-feature-container\" class=\"kd-main-product-feature-container\"\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-feature-continer kd-flex-row-2\"\u003e \u003cdiv class=\"kd-prouduct-feature-item kd-prouduct-feature-content\"\u003e \u003ch2\u003eLANAIR XT200 Waste Oil Heater Value Package 3\u003c\/h2\u003e \u003cp\u003e\u003cem\u003ePlease note: this package is configured for a roof-mount vent.\u003c\/em\u003e\u003c\/p\u003e \u003cp\u003eThe question that decides whether a roof-vented heater is straightforward or expensive is not the heater. It is the roof. \u003cstrong\u003eThe flashing in this package is specified for pitches from 0\/12 to 6\/12\u003c\/strong\u003e, which covers everything from a flat commercial deck to a moderately pitched workshop roof, and the kit includes the roof support bracket, storm collar and finishing collar that make the penetration weathertight and properly carried. If your roof falls inside that range, this is a package you can hand to an installer complete. If it is steeper, tell us before you order rather than after.\u003c\/p\u003e \u003cp\u003eThe heater is the XT200: up to 200,000 BTUH across roughly 5,000 square feet, 1.44 GPH fuel input, in a fine-grained galvanized cabinet with an internal fan and adjustable locking louvers on the discharge. The chimney is 6\" Class A and the kit is sized for a 16' eave.\u003c\/p\u003e \u003ch3\u003eWhy a vertical flue is usually the better installation\u003c\/h3\u003e \u003cp\u003eGiven a free choice, most installers take a chimney straight up. A vertical run develops draft naturally as hot gas rises, so the flue does more of its own work and is less sensitive to wind conditions around the building than a sidewall termination. It also keeps the whole of your wall area available — in a workshop that is racking, benches, a compressor, roller doors and, sooner or later, something you did not plan for. The cost of that choice is a hole in the roof, and everything in this kit exists to make that hole a controlled detail rather than a leak waiting for the first storm.\u003c\/p\u003e \u003cp\u003eThe trade is genuinely two-sided, and worth thinking about before you commit: a roof penetration on a leased building may need a landlord's consent, and on a membrane roof it needs someone who works on membrane roofs. If either of those is a problem, the wall-mount version of this package exists for exactly that reason.\u003c\/p\u003e \u003ch3\u003eWill It Fit?\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eRoof pitch.\u003c\/strong\u003e The supplied flashing covers 0\/12 through 6\/12. Measure yours before ordering.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eEave height.\u003c\/strong\u003e The kit is specified for a 16' eave. A materially taller building needs additional pipe.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFlue route.\u003c\/strong\u003e The chimney has to rise clear of trusses, services, lighting and anything sitting on the deck above.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCabinet and hanging point.\u003c\/strong\u003e 24\" x 40.25\" x 48\" (L x W x H), suspended, hanging weight 413 lbs. Have the structure confirmed by someone qualified.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eServices.\u003c\/strong\u003e A dedicated 120V, 20 amp circuit, plus compressed air at 2 CFM and 12-15 PSI available continuously while the burner is firing.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eClearances to combustible material, the roof penetration detail, the structural assessment of the hanging point, fuel storage arrangements and any permit or inspection required in your jurisdiction are the buyer's responsibility. We supply the equipment and the manufacturer's documentation; approval of the installation is not ours to give.\u003c\/p\u003e \u003ch3\u003eWhat you are actually buying, in fuel terms\u003c\/h3\u003e \u003cp\u003eA waste oil heater changes two lines on a shop's accounts at once, which is why the payback arithmetic surprises people. The first line is disposal — whatever you currently pay a licensed hauler to remove used oil. The second is heating fuel, which the same oil now replaces. At 1.44 GPH the consumption side is easy to model against the volume you already know you collect.\u003c\/p\u003e \u003cp\u003eThe XT200 takes used crankcase oil up to 50 weight, conventional or synthetic, used automatic transmission fluid, and #1 and #2 fuel oil. In other words most of what a general repair shop drains, rather than a narrow specification you would have to sort your waste stream to meet.\u003c\/p\u003e \u003ch3\u003eThe kit, itemised\u003c\/h3\u003e \u003cp\u003eSized for a 16' eave:\u003c\/p\u003e \u003ctable\u003e \u003cthead\u003e\u003ctr\u003e \u003cth scope=\"col\"\u003eComponent\u003c\/th\u003e \u003cth scope=\"col\"\u003eQty\u003c\/th\u003e \u003c\/tr\u003e\u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eRoof flashing, 0\/12 to 6\/12 pitch\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStorm collar\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRoof support bracket\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eChimney cap\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eClass A chimney pipe, 36\"\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eClass A chimney pipe, 24\"\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFinishing collar\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSlip connector, 14\"\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eElbow, 90°\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBlack pipe, 24\"\u003c\/td\u003e \u003ctd\u003e4\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBlack tee pipe with cap\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003eThe Class A sections are the insulated pipe that passes through the roof structure; the black pipe is single-wall connector for the run inside the heated space. They are not interchangeable and substituting one for the other is a fire risk. The tee with a cap is the flue's cleaning access, which on an oil-fired appliance you will use.\u003c\/p\u003e \u003ch3\u003ePerfect For\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eOwner-occupied shops with a conventional roof\u003c\/strong\u003e in the 0\/12 to 6\/12 range and a clear route up.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eOpen workshops up to about 5,000 square feet\u003c\/strong\u003e where louvered discharge covers the working area.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBuildings where wall space is fully committed\u003c\/strong\u003e and a sidewall termination would be in the way.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eGeneral repair and fleet shops\u003c\/strong\u003e already paying for used oil collection.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhat's in the Box\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eLanair XT200 waste oil heater\u003c\/li\u003e \u003cli\u003eRoof-mount chimney kit as itemised above, sized for a 16' eave\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eStorage tank, pump and oil lines are configured per site and are not included here. If you want the list checked against your building first, \u003ca href=\"https:\/\/mechanicsuperstore.com\/pages\/contact\"\u003eget in touch\u003c\/a\u003e.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeat range (BTUH)\u003c\/th\u003e \u003ctd\u003e200,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeating area (sq. ft.)\u003c\/th\u003e \u003ctd\u003e5,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eFuel input (GPH)\u003c\/th\u003e \u003ctd\u003e1.44\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eVent configuration\u003c\/th\u003e \u003ctd\u003eRoof mount, 6\" Class A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eFlashing pitch range\u003c\/th\u003e \u003ctd\u003e0\/12 to 6\/12\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCabinet (L x W x H)\u003c\/th\u003e \u003ctd\u003e24\" x 40.25\" x 48\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHanging weight\u003c\/th\u003e \u003ctd\u003e413 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCabinet finish\u003c\/th\u003e \u003ctd\u003eFine-grained galvanized\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAxial fan (CFM)\u003c\/th\u003e \u003ctd\u003e2,600\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCombustion chamber\u003c\/th\u003e \u003ctd\u003e12 gauge cold-rolled steel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDuctable option\u003c\/th\u003e \u003ctd\u003eCall\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e \u003ctd\u003e120V, 20 amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCompressed air\u003c\/th\u003e \u003ctd\u003e2 CFM at 12-15 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eApprovals, and the limits of one\u003c\/h3\u003e \u003cp\u003eLanair states that all of its units are UL listed, which is a real credential and more than a lot of shop equipment carries. Be clear about its scope, though: a listing covers the appliance, not your installation. The flue route, the roof penetration, clearances to combustibles, combustion air and the way you store fuel oil all sit under local mechanical and fire codes, and an inspector or an insurer can require things of the installation that no product listing speaks to. Think of the listing as the first document you will be asked for, not the whole file.\u003c\/p\u003e \u003ch3\u003eShipping and Delivery\u003c\/h3\u003e \u003cp\u003eThis ships as freight inside the lower 48 states, free of charge. It arrives as several pieces — heater plus vent components — so count them against the paperwork before the driver leaves. Getting it off the trailer is the receiver's job: arrange a forklift and an operator, or choose terminal pickup and collect it with your own equipment. Residential delivery is available and carries an extra fee. Damage or shortage must be written on the bill of lading at the point of signature; a clean signature closes the door on most claims.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eBacked by the manufacturer's warranty. Current terms and the claim process live on our \u003ca href=\"https:\/\/mechanicsuperstore.com\/pages\/warranty-claims\"\u003ewarranty claims page\u003c\/a\u003e. One request that applies to every oil-fired unit we sell: log the claim before anything is taken apart. Stripping a burner down to diagnose it removes the evidence an assessor needs, and it is the usual cause of a slow claim on an otherwise clear-cut fault. Photograph the unit as found, note the hour meter reading, and speak to us first.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-spec-container\" class=\"kd-main-product-spec-container\"\u003e \u003ch3 class=\"h3 accordion\"\u003eProduct Specifications\u003c\/h3\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-spec-continer kd-flex-row\"\u003e \u003cdiv class=\"kd-prouduct-spec-item\"\u003e \u003ctable border=\"0\" cellspacing=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHeat Range (BTUH)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e200,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Input (GPH)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e1.44\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Type\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eWaste oil (used crankcase oil up to 50 wt), used synthetic oil, used #1 and #2 fuel oil, used C.C. synthetic ATF #1 and #2, used automatic transmission fluid\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHeating Area (sq. ft.)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e5,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003ePower Supply (AC)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e120 V-60Hz 20 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCabinet Dimensions (L x W x H)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e24\" x 40.25\" x 48\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHanging Weight (lbs.)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e413\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eAxial Fan (CFM)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e2,600\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eChimney Pipe\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e6\" Class A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCompressed Air\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e2 CFM – 12-15 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCombustion Chamber\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e12 Gauge CRS\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eDuctable Option\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eCall\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eChimney Location\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eTop and Side\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-downloads-container\" class=\"kd-main-product-downloads-container\"\u003e \u003ch3 class=\"h3 accordion\"\u003eDownloads\u003c\/h3\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-downloads-continer kd-flex-row\"\u003e \u003cdiv class=\"kd-prouduct-downloads-item\"\u003e \u003cdiv class=\"kd-img-container kd-flex-row\"\u003e \u003cdiv class=\"kd-img-item\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0632\/5442\/9831\/files\/vector.png?v=1742916126\" alt=\"\"\u003e \u003ch5\u003eBrochure\u003c\/h5\u003e \u003c\/div\u003e \u003cdiv class=\"kd-img-item\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0632\/5442\/9831\/files\/untitled.png?v=1742916130\" alt=\"\"\u003e \u003ch5\u003eManual\u003c\/h5\u003e \u003c\/div\u003e \u003cdiv class=\"kd-img-item\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0632\/5442\/9831\/files\/vector-1.png?v=1742916133\" alt=\"\"\u003e \u003ch5\u003eWarranty\u003c\/h5\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"kd-prouduct-downloads-item\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e","brand":"Lanair Products LLC","offers":[{"title":"Default Title","offer_id":49287133397146,"sku":"81012003","price":7089.76,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/lanair-xt200-waste-oil-heater-value-package-3","provider":"My Store","version":"1.0","type":"link"}