{"product_id":"lanair-xtd200-waste-oil-heater-value-package-1","title":"LANAIR XTD200 Waste Oil Heater Value Package 1","description":"\u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-feature-container\" class=\"kd-main-product-feature-container\"\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-feature-continer kd-flex-row-2\"\u003e \u003cdiv class=\"kd-prouduct-feature-item kd-prouduct-feature-content\"\u003e \u003ch2\u003eLANAIR XTD200 Waste Oil Heater Value Package 1\u003c\/h2\u003e \u003cp\u003eWaste oil installations rarely fail on the heater. They fail on the chimney — the wrong pipe in the wrong place, a missing collar, no way to clean the flue once soot starts to build. This package exists to remove that failure mode: the ductable XTD200 supplied together with a \u003cstrong\u003ecomplete flue kit specified for a 16-foot eave\u003c\/strong\u003e, including both grades of pipe the job needs and the capped tee that lets you clean the run afterwards.\u003c\/p\u003e \u003cp\u003eThe heater is the ductable model in Lanair's line, rated at 200,000 BTUH across roughly 5,000 square feet at a fuel input of 1.44 GPH, with the chimney able to leave the cabinet from the top or the left side. It burns \u003cstrong\u003e100%\u003c\/strong\u003e used synthetic oil, along with used crankcase oil up to 50 weight, used automatic transmission fluid, and #1 and #2 fuel oil.\u003c\/p\u003e \u003ch3\u003eTwo kinds of pipe, and why the difference is not optional\u003c\/h3\u003e \u003cp\u003eA flue kit for this class of appliance contains two materially different products, and confusing them is the single most consequential error an inexperienced installer makes.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eClass A chimney pipe\u003c\/strong\u003e is insulated, double-walled, and rated to pass through building fabric — a roof, a ceiling, a wall — while keeping its outer surface at a temperature that will not ignite what it touches. \u003cstrong\u003eBlack pipe\u003c\/strong\u003e is single-wall connector pipe, intended only for the visible run inside the heated space between the appliance and the start of the Class A section. Black pipe is cheaper and easier to work, which is exactly why it sometimes ends up in a penetration where Class A belongs. That is not a saving, it is a fire.\u003c\/p\u003e \u003cp\u003eThe kit here supplies both, in the quantities the geometry usually calls for, along with the storm collar and finishing collar that seal the transitions, a roof support bracket to carry the weight of the chimney rather than hanging it off the heater, and a 90° elbow and 14\" slip connector for the offset almost every real installation needs.\u003c\/p\u003e \u003ch3\u003eThe cleaning access nobody notices until they need it\u003c\/h3\u003e \u003cp\u003eOne item in the list deserves more attention than it gets: the black tee pipe with a cap. It looks like a fitting and it is a maintenance feature. Burning used fluid deposits residue in the flue as well as in the chamber, and a straight run with no access point can only be cleaned by taking it down. The capped tee gives you a port to brush the run through from. On an appliance you intend to keep for a decade, that is the difference between an hour's job and an afternoon with the flue in pieces on the floor.\u003c\/p\u003e \u003ch3\u003eThe kit, itemised\u003c\/h3\u003e \u003cp\u003eSpecified for a 16-foot eave:\u003c\/p\u003e \u003ctable\u003e \u003cthead\u003e\u003ctr\u003e \u003cth scope=\"col\"\u003ePart\u003c\/th\u003e \u003cth scope=\"col\"\u003eCount\u003c\/th\u003e \u003c\/tr\u003e\u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eClass A chimney pipe, 24\"\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eClass A chimney pipe, 36\"\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBlack pipe, 24\"\u003c\/td\u003e \u003ctd\u003e4\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBlack tee pipe with cap\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eElbow, 90°\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSlip connector, 14\"\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRoof support bracket\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStorm collar\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFinishing collar\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRoof flashing, 0\/12 to 6\/12 pitch\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eChimney cap\u003c\/td\u003e \u003ctd\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eWill It Fit?\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eFlue route.\u003c\/strong\u003e Establish it before you choose a hanging position. The chimney constrains where the heater can go far more than the reverse, and the flashing supplied covers pitches from 0\/12 to 6\/12.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eEave height.\u003c\/strong\u003e The kit is sized on a 16-foot eave; a taller building needs additional pipe.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCabinet.\u003c\/strong\u003e 24\" x 40.5\" x 56\" (H x W x D) — a deep body, and depth is the dimension most often misjudged when planning a position.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSuspension.\u003c\/strong\u003e 523 lbs hanging weight. Have the structural capacity of the mounting point confirmed by somebody qualified.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eServices.\u003c\/strong\u003e 120V at 20 amps on a dedicated circuit, plus 2 CFM of compressed air at 12-15 PSI available whenever the burner is firing.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eClearances to combustible material, the penetration detail, the structural assessment, fuel storage arrangements and any permit or inspection your jurisdiction requires are the buyer's responsibility. We supply the equipment and the manufacturer's documentation; approving the installation is not ours to do.\u003c\/p\u003e \u003ch3\u003eDuctable, and the fuel it will take\u003c\/h3\u003e \u003cp\u003eThe D cabinet is the one that can feed duct, which matters if your building is not a single open volume — a partitioned parts store, an office built into a corner, a wash bay behind a wall. In a fully open shop it makes no difference to performance and you can disregard it.\u003c\/p\u003e \u003cp\u003eThe fuel specification is more universally relevant. Burning \u003cstrong\u003e100%\u003c\/strong\u003e used synthetic oil is now the requirement rather than the bonus, because that is increasingly what comes out of a modern drain pan. Behind the burner is a 12 gauge cold-rolled steel combustion chamber with a hinged clean-out door and a side access panel onto the collector box, plus an hour meter, a prime switch and a noncontinuous spark transformer.\u003c\/p\u003e \u003ch3\u003ePerfect For\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eFirst installations\u003c\/strong\u003e, where having the whole flue specified and boxed removes the commonest cause of delay.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBuildings of roughly 5,000 square feet\u003c\/strong\u003e with a partition or two to heat past.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRoofs in the 0\/12 to 6\/12 pitch range\u003c\/strong\u003e with an eave around 16 feet.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eShops running current vehicles\u003c\/strong\u003e whose waste stream is largely synthetic.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhat's in the Box\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eLanair XTD200 waste oil heater\u003c\/li\u003e \u003cli\u003eChimney kit as itemised above, sized for a 16-foot eave\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eStorage tank, transfer pump and oil lines are configured per site and are not included. If you want the kit checked against your building before ordering, \u003ca href=\"https:\/\/mechanicsuperstore.com\/pages\/contact\"\u003esend us the details\u003c\/a\u003e.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeat range (BTUH)\u003c\/th\u003e \u003ctd\u003e200,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeating area (sq. ft.)\u003c\/th\u003e \u003ctd\u003e5,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eFuel input (GPH)\u003c\/th\u003e \u003ctd\u003e1.44\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eChimney\u003c\/th\u003e \u003ctd\u003e6\" Class A, top or left side\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eFlashing pitch range\u003c\/th\u003e \u003ctd\u003e0\/12 to 6\/12\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCabinet (H x W x D)\u003c\/th\u003e \u003ctd\u003e24\" x 40.5\" x 56\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHanging weight\u003c\/th\u003e \u003ctd\u003e523 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDuctable\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCombustion chamber\u003c\/th\u003e \u003ctd\u003e12 gauge cold-rolled steel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e \u003ctd\u003e120V, 20 amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCompressed air\u003c\/th\u003e \u003ctd\u003e2 CFM at 12-15 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eApprovals — read this before you order\u003c\/h3\u003e \u003cp\u003eThe specification data behind this listing does not state an independent safety listing for the unit. That is not the same as saying it is unsafe, but it is a distinction you should make deliberately rather than by default: a manufacturer's own declaration against a standard and a listing issued by an independent testing laboratory are different documents, and where oil-fired appliances and their flues are concerned, codes officers, commercial insurers and fleet safety policies often ask for the second one by name. If any of those govern your site, ask us for the current documentation for this model and get the requirement settled in writing before you buy.\u003c\/p\u003e \u003ch3\u003eShipping and Delivery\u003c\/h3\u003e \u003cp\u003eThis item ships free within the lower 48 states, so there is nothing to add at checkout. Several pieces travel together here, so the piece count is worth checking against the paperwork while the driver is still on site. Unloading is the receiver's responsibility — a forklift and someone to operate it, or terminal pickup with your own equipment. Residential delivery is available at an additional fee. Write any damage or shortage on the bill of lading before signing it; after a clean signature there is very little to work with. The current listing also states a processing window of 5-7 business days before dispatch, which is processing rather than transit — we do not promise a delivery date.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eManufacturer's warranty applies. Current terms and the claim procedure are published on our \u003ca href=\"https:\/\/mechanicsuperstore.com\/pages\/warranty-claims\"\u003ewarranty claims page\u003c\/a\u003e. Log the claim before anything is taken apart. Dismantling a burner or chamber to investigate is the most frequent reason a straightforward claim slows down, because the evidence goes with it. Photograph the fault as found, record the hour meter reading, and speak to us before the tools come out.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-spec-container\" class=\"kd-main-product-spec-container\"\u003e \u003ch3 class=\"h3 accordion\"\u003eProduct Specifications\u003c\/h3\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-spec-continer kd-flex-row\"\u003e \u003cdiv class=\"kd-prouduct-spec-item\"\u003e \u003ctable border=\"0\" cellspacing=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHeat Range (BTUH)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e200,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Input (GPH)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e1.44\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Type\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eWaste oil (used crankcase oil up to 50 wt), used synthetic oil, used #1 and #2 fuel oil, used C.C. synthetic ATF #1 and #2, used automatic transmission fluid\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Type\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eUsed crankcase oil up to 50 wt (conventional or synthetic), used automatic transmission fluid, #1 and #2 fuel oil (diesel)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHeating Area (sq. ft.)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e5,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003ePower Supply (AC)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e120 V-60Hz 20 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCabinet Dimensions (H x W x D)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e24\" x 40.5\" x 56\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHanging Weight (lbs.)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e523\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eChimney Pipe\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e6\" Class A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCompressed Air\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e2 CFM – 12-15 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCombustion Chamber\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e12 Gauge CRS\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eDuctable Option\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eChimney Location\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eTop and Left Side\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-downloads-container\" class=\"kd-main-product-downloads-container\"\u003e \u003ch3 class=\"h3 accordion\"\u003eDownloads\u003c\/h3\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-downloads-continer kd-flex-row\"\u003e \u003cdiv class=\"kd-prouduct-downloads-item\"\u003e \u003cdiv class=\"kd-img-container kd-flex-row\"\u003e \u003cdiv class=\"kd-img-item\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0632\/5442\/9831\/files\/vector.png?v=1742916126\" alt=\"\"\u003e \u003ch5\u003eBrochure\u003c\/h5\u003e \u003c\/div\u003e \u003cdiv class=\"kd-img-item\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0632\/5442\/9831\/files\/untitled.png?v=1742916130\" alt=\"\"\u003e \u003ch5\u003eManual\u003c\/h5\u003e \u003c\/div\u003e \u003cdiv class=\"kd-img-item\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0632\/5442\/9831\/files\/vector-1.png?v=1742916133\" alt=\"\"\u003e \u003ch5\u003eWarranty\u003c\/h5\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"kd-prouduct-downloads-item\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e","brand":"Lanair Products LLC","offers":[{"title":"Default Title","offer_id":49287133528218,"sku":"81012021","price":7014.06,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/lanair-xtd200-waste-oil-heater-value-package-1","provider":"My Store","version":"1.0","type":"link"}