{"product_id":"lanair-xtd300-waste-oil-heater-value-package-3","title":"LANAIR XTD300 Waste Oil Heater Value Package 3","description":"\u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-feature-container\" class=\"kd-main-product-feature-container\"\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-feature-continer kd-flex-row-2\"\u003e \u003cdiv class=\"kd-prouduct-feature-item kd-prouduct-feature-content\"\u003e \u003cp\u003e\u003cstrong\u003ePackage 3 vents through the roof.\u003c\/strong\u003e Mechanically it is the same Lanair XTD300 as the wall-vent package on our site; what differs is the flue kit in the crate and, consequently, what your installer does on day one. A vertical run through the roof deck generally gives the most reliable natural draft and keeps the flue out of the way of doors, walkways and anything parked alongside the building — which is why it remains the default choice where the roof is yours to penetrate.\u003c\/p\u003e \u003cp\u003eUnderneath the venting decision sits a 300,000 BTUH ceiling-hung heater rated for areas up to 10,000 square feet, burning oil your shop currently pays somebody to take away.\u003c\/p\u003e \u003ch3\u003eThe economics before the engineering\u003c\/h3\u003e \u003cp\u003eMost heating equipment is judged on efficiency. This one is judged on arbitrage. Drain oil is a waste stream with a removal cost attached; run it through a burner and it becomes heat you would otherwise buy from a utility. The saving is therefore the fuel you no longer purchase plus the disposal you no longer pay for, and both halves grow whenever energy or hauling rates rise. Against that, a waste oil heater asks for something in return: attention. It is an appliance you maintain rather than one you install and forget.\u003c\/p\u003e \u003ch3\u003eWhich oils, and why the list matters in February\u003c\/h3\u003e \u003cp\u003eApproved fuels run to used crankcase oil up to 50 wt, conventional or synthetic; used automatic transmission fluid and synthetic ATF; and #1 and #2 fuel oil, meaning diesel. Read that list as a supply-security question rather than a compatibility one. A single-service shop can run short of drain oil in a hard cold snap, exactly when the burner is working hardest. Being able to top the tank with diesel, or to bring transmission fluid into the same tank, is what keeps the building warm when your own oil generation cannot keep pace.\u003c\/p\u003e \u003ch3\u003eServiceability, in detail\u003c\/h3\u003e \u003cp\u003eThe parts of this heater that Lanair has revised are almost all about the hour you spend cleaning it. The combustion chamber door is hinged rather than bolted, so it opens with the panel supported instead of balanced. The collector box is reached through a large side-access panel. The burner is built to come out easily.\u003c\/p\u003e \u003cp\u003eOperationally there is an hour meter, which turns service intervals into a measured number rather than a memory; a prime switch; and a non-continuous spark transformer, which sparks to establish the flame rather than running constantly. The combustion chamber itself is 10 gauge CRS, chosen for the component that endures the most thermal cycling in the machine.\u003c\/p\u003e \u003ch3\u003ePlanning the installation\u003c\/h3\u003e \u003cp\u003eThe single figure to resolve first is the hanging weight: 696 lbs, carried by your building’s structure, not by the floor. Get that assessed by someone qualified before the heater arrives, and choose the mounting height with cleaning in mind — the hinged door and the side panel both have to be reachable, or the maintenance that makes this appliance worthwhile quietly stops happening.\u003c\/p\u003e \u003cp\u003eThe cabinet is 36\" x 45.5\" x 54\" (height x width x depth). The flue is 8\" Class A pipe, and the chimney can exit the top or the left side of the cabinet, which usually decides where between the joists the unit hangs. Electrical supply is 120 V at 20 Amps. The burner also needs compressed air at 2 CFM and 15-18 PSI, continuously while firing, so check that your compressor has that spare rather than assuming it. At full fire the unit consumes 2.14 gallons per hour, and that is the number to hold against both your tank size and your monthly oil generation.\u003c\/p\u003e \u003cp\u003eConfirming structural capacity, clearances, the vent route and local approval is the buyer’s responsibility. We will help with the specification; we cannot inspect your building.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeat range\u003c\/th\u003e \u003ctd\u003e300,000 BTUH\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eFuel input\u003c\/th\u003e \u003ctd\u003e2.14 gallons per hour\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeating area\u003c\/th\u003e \u003ctd\u003eup to 10,000 square feet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e \u003ctd\u003e120 V, 20 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCompressed air\u003c\/th\u003e \u003ctd\u003e2 CFM at 15-18 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCabinet (H x W x D)\u003c\/th\u003e \u003ctd\u003e36\" x 45.5\" x 54\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHanging weight\u003c\/th\u003e \u003ctd\u003e696 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eChimney pipe\u003c\/th\u003e \u003ctd\u003e8\" Class A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eChimney location\u003c\/th\u003e \u003ctd\u003eTop and left side\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCombustion chamber\u003c\/th\u003e \u003ctd\u003e10 gauge CRS\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDuctable\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003ePerfect For\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eOwner-occupied shops\u003c\/strong\u003e where a roof penetration is straightforward to authorise and flash properly.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBuildings with obstructed walls\u003c\/strong\u003e — parking, walkways or neighbouring structures that rule out a side vent.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh-volume oil change and fleet operations\u003c\/strong\u003e generating enough drain oil to feed a 2.14 gallons per hour burner.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eWorkshops up to 10,000 square feet\u003c\/strong\u003e that want the option to duct heat rather than rely on a single throw.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhat the package includes\u003c\/h3\u003e \u003cp\u003ePackage 3 pairs the heater with a complete roof-vent chimney kit. The current product copy names a chimney cap, Class A chimney pipes, roof flashing, a storm collar and the remaining components needed to complete the installation.\u003c\/p\u003e \u003cp\u003eWhat our data does not do is give you a counted parts list for this package, and a chimney kit is bought against a specific roof pitch and eave height. Tell us your roof pitch and the height of the run before you order and we will confirm the exact contents with Lanair, rather than have you discover a missing length of pipe with the installer already on site. One further correction while we are here: an older version of this listing referred to a bulk waste oil storage tank of a stated size. No tank appears anywhere in the manufacturer’s specification for this heater, so do not assume one is included — ask us.\u003c\/p\u003e \u003ch3\u003eCertification and compliance\u003c\/h3\u003e \u003cp\u003eOur data for this package records no listing by an independent testing laboratory, and we will not suggest one. For an oil-fired, ceiling-suspended appliance that is a live question rather than paperwork: installation typically needs a mechanical permit, and inspectors ask for listing documentation. Contact us before purchase and we will obtain what the manufacturer holds. Rules on burning used oil also vary between jurisdictions, so confirm yours locally.\u003c\/p\u003e \u003ch3\u003eDelivery and inspection\u003c\/h3\u003e \u003cp\u003eFreight shipment, contiguous United States. You will need equipment or hands to unload a heavy crated appliance, or you can take terminal pickup instead; a residential address is possible but attracts a residential fee, and a commercial delivery point is usually simpler for something this size.\u003c\/p\u003e \u003cp\u003eBefore signing, walk the pallet. Look at the cabinet, the burner assembly and every chimney carton, and write any damage on the bill of lading while the driver is still there. Damage noted at delivery stays claimable; damage found the next morning generally does not.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eWarranty claims are handled through our \u003ca href=\"https:\/\/mechanicsuperstore.com\/pages\/warranty-claims\"\u003ewarranty claims page\u003c\/a\u003e. Do not disassemble the heater before the claim is open — photograph the fault and call us first. Keep your cleaning and service records too: with fuel-burning equipment, a documented maintenance history is frequently what decides a warranty conversation.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-spec-container\" class=\"kd-main-product-spec-container\"\u003e \u003ch3 class=\"h3 accordion\"\u003eProduct Specifications\u003c\/h3\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-spec-continer kd-flex-row\"\u003e \u003cdiv class=\"kd-prouduct-spec-item\"\u003e \u003ctable border=\"0\" cellspacing=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHeat Range (BTUH)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e300,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Input (GPH)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e2.14\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Type\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eWaste oil (used crankcase oil up to 50 wt), used synthetic oil, used #1 and #2 fuel oil, used C.C. synthetic ATF #1 and #2, used automatic transmission fluid\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Type\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eUsed crankcase oil up to 50 wt (conventional or synthetic), used automatic transmission fluid, #1 and #2 fuel oil (diesel)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHeating Area (sq. ft.)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e10,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003ePower Supply (AC)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e120 V-60Hz 20 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCabinet Dimensions (H x W x D)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e36\" x 45.5\" x 54\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHanging Weight (lbs.)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e696\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eChimney Pipe\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e8\" Class A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCompressed Air\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e2 CFM – 15-18 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCombustion Chamber\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e10 Gauge CRS\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eDuctable Option\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eChimney Location\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eTop and Left Side\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e","brand":"Lanair Products LLC","offers":[{"title":"Default Title","offer_id":49287134576794,"sku":"81013023","price":9981.69,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/lanair-xtd300-waste-oil-heater-value-package-3","provider":"My Store","version":"1.0","type":"link"}