{"product_id":"lanair-xtd300-waste-oil-heater","title":"LANAIR XTD300 Waste Oil Heater","description":"\u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-feature-container\" class=\"kd-main-product-feature-container\"\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-feature-continer kd-flex-row-2\"\u003e \u003cdiv class=\"kd-prouduct-feature-item kd-prouduct-feature-content\"\u003e \u003ch2\u003eLanair XTD300 Waste Oil Heater — the ductable unit, sold on its own\u003c\/h2\u003e  \u003cp\u003eThe XTD300 is the heater by itself: no tank, no chimney kit, no ancillaries. That is the right way to buy it if your building already has a used-oil tank and a flue you intend to reuse, and it is the wrong way to buy it if you are starting from an empty wall. The reason to reach for the XTD rather than the XT sitting next to it in the range is one line in the spec table: \u003cstrong\u003eDuctable Option — Yes\u003c\/strong\u003e. The XTD is designed to have ductwork hung off it, so the heat can be taken away from the cabinet and delivered where the work happens.\u003c\/p\u003e  \u003cp\u003eThat single word changes what the machine is for. A free-blowing shop heater warms the volume of air around itself and relies on the building to move it. A ducted heater lets you decide: a run down a long bay, a drop over a wash-down area, a branch into a parts room that would otherwise stay cold. If you have a shop with a partition wall in it, that flexibility is usually worth more than raw output.\u003c\/p\u003e  \u003ch3\u003eSettle the electrical supply before delivery, not after\u003c\/h3\u003e  \u003cp\u003eThis is the one item on the page we want you to read twice, because the published figures for it differ. \u003cstrong\u003eThe spec table on this listing states the power supply as two 120 V legs\u003c\/strong\u003e, and the manufacturer's overview text on this same product agrees: it describes a supply of two 120 V legs plus compressed air. \u003cstrong\u003eThe packaged versions of the same heater, listed separately on this site, state a single 120-volt supply instead.\u003c\/strong\u003e Those are not the same circuit, and they are not the same job for an electrician.\u003c\/p\u003e  \u003cp\u003eBoth figures are printed above, each against the listing that publishes it, and the right move is to \u003cstrong\u003econfirm the supply with us in writing before you book an electrician\u003c\/strong\u003e. Getting this right in advance costs a phone call. Getting it wrong means a second visit and a heater sitting on a pallet in the meantime.\u003c\/p\u003e  \u003ch3\u003eCompressed air is not optional\u003c\/h3\u003e  \u003cp\u003eThe XTD300 atomises its fuel with shop air, and it needs \u003cstrong\u003e2 CFM at 15-18 PSI\u003c\/strong\u003e, continuously, whenever the burner runs. A compressor that normally wakes up for an impact gun is now heating plant, and it will cycle through the night in January. The air also has to be clean and dry — wet air is how a heating season turns into a service call — so plan for a dryer and a filter on the line feeding the heater.\u003c\/p\u003e  \u003ch3\u003eServiceability, and why it decides how much you like this heater\u003c\/h3\u003e  \u003cp\u003eEvery waste oil heater accumulates ash. What does not burn stays in the combustion chamber and works its way toward the collector box. A heater you can open is a heater that gets cleaned; a heater that fights you gets cleaned once. The XTD300 is built around that: the chamber door is hinged rather than bolted, there is a large side-access panel to the collector box, and the burner lifts out rather than being dismantled in place. An hour meter tells you when a cleanout is due, a prime switch handles the fuel line, and a noncontinuous spark transformer means the ignition circuit is not live every minute the heater is.\u003c\/p\u003e  \u003cp\u003eThe combustion chamber itself is \u003cstrong\u003e10-gauge cold-rolled steel\u003c\/strong\u003e. That is a thickness chosen for the scraping and thermal cycling a waste oil chamber lives through, and it is a reasonable proxy for how many seasons the unit has in it.\u003c\/p\u003e  \u003ch3\u003eWill it fit?\u003c\/h3\u003e  \u003cp\u003eThis is a hanging unit, so the questions are structural before they are dimensional. The cabinet measures \u003cstrong\u003e36\" high x 45.5\" wide x 54\" deep\u003c\/strong\u003e and its hanging weight is \u003cstrong\u003e696 lbs\u003c\/strong\u003e — that load goes into your building's structure, and confirming the structure can take it is the customer's responsibility, not ours and not the carrier's. If you are hanging it from a wood-framed roof or an older steel building, have someone qualified look at the connection points before the heater arrives.\u003c\/p\u003e  \u003cp\u003eVenting is \u003cstrong\u003e8\" Class A\u003c\/strong\u003e chimney, and the flue can leave the cabinet at the \u003cstrong\u003etop or the left side\u003c\/strong\u003e, which is what usually decides where in the bay it can go. Leave working room in front of the chamber door and beside the collector-box panel; a heater installed in a corner where the door cannot swing is a heater that never gets serviced properly. Clearances to combustibles, chimney height above the roofline and any permit requirement are set by your local mechanical code — check them before you buy, not after.\u003c\/p\u003e  \u003ch3\u003eSpecifications\u003c\/h3\u003e  \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e \u003ctd\u003eXTD300\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeat range (BTUH)\u003c\/th\u003e \u003ctd\u003e300,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeating area (sq. ft.)\u003c\/th\u003e \u003ctd\u003e10,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eFuel input (GPH)\u003c\/th\u003e \u003ctd\u003e2.1 on this listing — see the note below\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCabinet (H x W x D)\u003c\/th\u003e \u003ctd\u003e36\" x 45.5\" x 54\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHanging weight\u003c\/th\u003e \u003ctd\u003e696 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eChimney pipe\u003c\/th\u003e \u003ctd\u003e8\" Class A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eChimney location\u003c\/th\u003e \u003ctd\u003eTop and left side\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCompressed air\u003c\/th\u003e \u003ctd\u003e2 CFM at 15-18 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCombustion chamber\u003c\/th\u003e \u003ctd\u003e10-gauge cold-rolled steel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDuctable\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e \u003ctd\u003eTwo 120 V legs on this listing — confirm with us\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e  \u003cp\u003eOne more figure to note: this listing gives the fuel input as 2.1 GPH, while the packaged versions of the same heater give 2.14 GPH. The gap is small and it does not change the sizing decision. \u003cstrong\u003eIf it decides yours, confirm the figure with us before you order.\u003c\/strong\u003e\u003c\/p\u003e  \u003ch3\u003ePerfect for\u003c\/h3\u003e  \u003cul\u003e \u003cli\u003e \u003cstrong\u003eAn established shop replacing a heater\u003c\/strong\u003e — the tank, the flue and the oil-collection habit already exist, and only the heater needs changing.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eA partitioned building\u003c\/strong\u003e — the ductable design is the whole argument for the XTD over the XT, and it only pays off if you have somewhere to run duct.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eA high-volume service bay\u003c\/strong\u003e — a shop generating its own used oil turns a disposal cost into a heating budget.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eA fleet or municipal garage\u003c\/strong\u003e — steady oil supply, a building that needs heat anyway, and a maintenance department that will actually do the cleanouts.\u003c\/li\u003e \u003c\/ul\u003e  \u003ch3\u003eWhat ships\u003c\/h3\u003e  \u003cp\u003eThe heater. This listing is for the XTD300 unit on its own, and nothing in our product data for it states a tank, a chimney kit or an ancillary package. If you need those, our XTD300 value packages bundle a chimney kit with the heater — and if you want a specific combination, ask us rather than assuming, because the packages differ from each other in ways the listings do not always spell out.\u003c\/p\u003e  \u003ch3\u003eSafety listing — what we can and cannot tell you\u003c\/h3\u003e  \u003cp\u003eWe are going to be straight about this rather than badge the page. \u003cstrong\u003eThe product data we hold for the XTD300 does not state a third-party safety listing.\u003c\/strong\u003e Some of the XT-series pages on this site do carry that claim from the manufacturer; this one does not, and we are not going to move a claim from one page to another because it would look better here.\u003c\/p\u003e  \u003cp\u003eThat distinction matters to a specific set of buyers. Insurers, fleet safety policies and local mechanical-code officials sometimes require a heating appliance to carry a recognised third-party listing, and a manufacturer's own statement is a different document from an independent laboratory's. If your insurer, your fleet policy or your building inspector requires one, \u003cstrong\u003eask us for the current listing documentation before you order\u003c\/strong\u003e and we will get it from Lanair. Do not take silence on a web page as an answer either way.\u003c\/p\u003e  \u003ch3\u003eFreight delivery, and what we need from you\u003c\/h3\u003e  \u003cp\u003eThis heater ships freight to the lower 48 states, crated, on a pallet. The driver brings it to your address; getting it off the truck is yours to arrange. A forklift or a dock makes it simple. If you have neither, take the shipment at the carrier's terminal and move it yourself — that option is open on every freight order we ship. Delivery to a residential address carries a residential fee, applied at checkout.\u003c\/p\u003e  \u003cp\u003eInspect before you sign. Walk the pallet, look for crushed corners, torn shrink and shifted banding, and write anything you find on the bill of lading while the driver is still there. Photograph it. A clean signature is the carrier's proof that the shipment arrived intact, and a damage claim opened afterwards is a much harder argument to win.\u003c\/p\u003e  \u003ch3\u003eWarranty\u003c\/h3\u003e  \u003cp\u003eCoverage is the manufacturer's, and the warranty document for this unit is in the Downloads section on this page. One piece of house advice that applies to every brand we sell: \u003cstrong\u003edo not take a part to pieces before you claim on it.\u003c\/strong\u003e A component that has been opened, modified or repaired in the field usually falls outside the terms. Stop, photograph what you have, and start the claim through our \u003ca href=\"https:\/\/mechanicsuperstore.com\/pages\/warranty-claims\"\u003ewarranty claims\u003c\/a\u003e page.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-spec-container\" class=\"kd-main-product-spec-container\"\u003e \u003ch3 class=\"h3 accordion\"\u003eProduct Specifications\u003c\/h3\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-spec-continer kd-flex-row\"\u003e \u003cdiv class=\"kd-prouduct-spec-item\"\u003e \u003ctable border=\"0\" cellspacing=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHeat Range (BTUH)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e300,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Input (GPH)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e2.1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Type\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eWaste oil (used crankcase oil up to 50 wt), used synthetic oil, used #1 and #2 fuel oil, used C.C. synthetic ATF #1 and #2, used automatic transmission fluid\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eFuel Type\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eUsed crankcase oil up to 50 wt (conventional or synthetic), used automatic transmission fluid, #1 and #2 fuel oil (diesel)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHeating Area (sq. ft.)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e10,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003ePower Supply (AC)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e(2)-120 V-60Hz 2 Legs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCabinet Dimensions (H x W x D)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e36\" x 45.5\" x 54\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eHanging Weight (lbs.)\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e696\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eChimney Pipe\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e8\" Class A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCompressed Air\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e2 CFM – 15-18 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eCombustion Chamber\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003e10 Gauge CRS\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eDuctable Option\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" width=\"50%\"\u003eChimney Location\u003c\/td\u003e \u003ctd align=\"right\" width=\"50%\"\u003eTop and Left Side\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e \u003cdiv id=\"kd-main-product-downloads-container\" class=\"kd-main-product-downloads-container\"\u003e \u003ch3 class=\"h3 accordion\"\u003eDownloads\u003c\/h3\u003e \u003cdiv class=\"panel\"\u003e \u003cdiv class=\"kd-product-downloads-continer kd-flex-row\"\u003e \u003cdiv class=\"kd-prouduct-downloads-item\"\u003e \u003cdiv class=\"kd-img-container kd-flex-row\"\u003e \u003cdiv class=\"kd-img-item\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0632\/5442\/9831\/files\/vector.png?v=1742916126\" alt=\"\"\u003e \u003ch5\u003eBrochure\u003c\/h5\u003e \u003c\/div\u003e \u003cdiv class=\"kd-img-item\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0632\/5442\/9831\/files\/untitled.png?v=1742916130\" alt=\"\"\u003e \u003ch5\u003eManual\u003c\/h5\u003e \u003c\/div\u003e \u003cdiv class=\"kd-img-item\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0632\/5442\/9831\/files\/vector-1.png?v=1742916133\" alt=\"\"\u003e \u003ch5\u003eWarranty\u003c\/h5\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"kd-prouduct-downloads-item\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"divider\"\u003e\u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-ew8kwapfc4\/images\/stencil\/original\/image-manager\/golden-bar.png?t=1681903157\" alt=\"\" width=\"1198\" height=\"8\"\u003e\u003c\/div\u003e","brand":"Lanair Products LLC","offers":[{"title":"Default Title","offer_id":49287134642330,"sku":"81013025","price":8561.47,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/lanair-xtd300-waste-oil-heater","provider":"My Store","version":"1.0","type":"link"}