{"product_id":"outback-power-radian-grid-tie-off-grid-inverter-gs8048-8000w-48","title":"Outback Power Radian Inverter GS8048A-01 | 8000w 48V | Grid Tie \/ Off Grid","description":"\u003cp\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cstrong\u003eOutback Power Radian Grid Tie\/ Off Grid Inverter GS8048 8000w 48VDC Advanced for AC Coupling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003eOutback's new \u003cstrong\u003eRadian inverter\u003c\/strong\u003e works equally well as a grid tie or off-grid inverter. There are two separate AC inputs, one for the bi-directional grid connection and one for a back-up generator. There is a built-in 50 A transfer switch at 120\/240 VAC. The output is 120\/240 VAC split phase in each unit for easy tie-in to US standard wiring and grid connections. The Radian features 8kW of continuous output power and can support large dynamic load variations and surge loads, making it well-suited for demanding commercial applications as well as residential use. With two power stages, it is able to provide high efficiency and redundancy for critical applications, and the modular design is field serviceable. The Radian can be parallel stacked with up to 10 inverters for 80kW total output. The Radian also has auxiliary controls which include a contact closure, a 12 VDC output signal and terminals for a remote on\/off switch.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003eThe inverter comes with a standard 5-year warranty. An optional 10-year extended warranty is available where required by state incentive programs. The Radian is for indoor use only. Dimensions are 28\"H x 16\"W x 8.7\"D. Weight is 125 lbs. Listed to UL 1741 for U.S. and Canada.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003eYou will also need a Mate 3, Hub 4 or 10, RTS, and an appropriate GSLC (below) to complete a Radian system.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGS Load Center (GSLC)\u003c\/strong\u003e is a wiring and circuit protection enclosure that mounts under the Radian inverter. It is available in three versions:\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003ebase GSLC\u003c\/strong\u003e includes positive and negative main inverter bus bars, a 500 A 50 mV shunt with negative terminal bar, the main DC positive breaker plate, ground ad neutral terminal bars, and 2 PV positive terminal bars. It can also accommodate up to 18 AC or DC panel mount breakers (10 top, 8 bottom), two main 175 A DC breakers and a FlexnetDC, which can be purchased separately. Up to two charge controls can mount on the right side (mounting brackets not included), and either the Hub4 or Hub10 can mount on the left side.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGSLC175-120\/240\u003c\/strong\u003e has everything that the basic unit has and also includes two 175 A DC main breakers, an AC output and bypass breakers with interlock plate, an AC grid and generator input breakers (50 A two pole), and six AC terminal bars (3 black, 3 red). It can also accommodate 10 additional panel mount breakers and one additional main breaker, which can be purchased separately.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGSLC175-PV-120\/240\u003c\/strong\u003e has everything that the other versions have and also includes two 80 A PV array breakers, a two pole GFDI 80 A breaker, three 500 A 50 mV shunts with shunt bus, and a FlexnetDC. The GFDI acts as the breaker between the control and positive bus, there are no other breakers added for this purpose. It can also accommodate 5 additional panel mount breakers, which can be purchased separately.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAC bypass\u003c\/strong\u003e assembly is only for use with a single Radian inverter. For multiple inverters, use the basic GSLC with added DC and AC breakers as needed (no bypass) and use external transfer switches for bypass and external AC load centers for output combining and input distribution. One GSLC is required for each Radian inverter, and each inverter requires two 175 A main DC breakers.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e\u003cspan\u003eThe GSLC is for indoor use only. Dimensions are 17\"H x 16\"W x 8.5\"D. Weight is 26, 37, or 38 lbs. Listed to UL 1741 for U.S. and Canada. More accessories for Outback can be found on the accessories page.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cdiv class=\"field field-name-field-products-tables field-type-text-long field-label-hidden\"\u003e \u003cdiv class=\"field-items\"\u003e \u003cdiv class=\"field-item even\"\u003e \u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"700\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd bgcolor=\"#ffff99\" class=\"tables-table-head\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd bgcolor=\"#ffff99\" class=\"tables-table-head\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eContinuous\u003cbr\u003eWatts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd bgcolor=\"#ffff99\" class=\"tables-table-head\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eBattery\u003cbr\u003evoltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd bgcolor=\"#ffff99\" class=\"tables-table-head\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eAC out volts\/\u003cbr\u003ehertz\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd bgcolor=\"#ffff99\" class=\"tables-table-head\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eNo load draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd bgcolor=\"#ffff99\" class=\"tables-table-head\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eCharger amps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd bgcolor=\"#ffff99\" class=\"tables-table-head\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eAC surge\u003cbr\u003eoutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd bgcolor=\"#ffff99\" class=\"tables-table-head\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eWeight (lbs)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd bgcolor=\"#ffff99\" class=\"tables-table-head\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eItem code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eGS8048\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e8000\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e48 VDC\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e120\/240 60HZ\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e30 W\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e115 A\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e12000 W\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003e125\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e030-04039\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"tables-table-head\" colspan=\"9\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003e\u003cstrong\u003eGS Load Centers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eGSLC\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eGS Load Center with inverter bars, breaker bus, shunt, neg, ground, neutral, and PV pos bus bars\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-02250\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eGSLC175-120\/240\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eGS Load Center with all items above plus 2 main 175 A breakers, AC IO\/Bypass, and 6 AC bus bars\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-02251\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eGSLC175-PV-120\/240\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eGS Load Center with all items above with 3 shunts, FNDC, 2 pole GFDI, and dual PV input breakers\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-02252\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"tables-table-head\" colspan=\"9\"\u003e \u003cp class=\"tables-table-head\"\u003e\u003cspan\u003eGS Load Center Accessories\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eGS-IOB-120\/240 VAC\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eGS AC input\/output\/bypass kit split phase 120\/240 VAC for single inverter only\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-07818\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eGS-SBUS\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eDC shunt bus for GS load center\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-00130\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eSTBB-BLACK\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eShort bus bar kit with black Insulators for GS load center\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-00132\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eSTBB-RED\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eShort bus bar kit with red Insulators for GS load center\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-00133\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003eSTBB-WHITE\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eShort bus bar kit with white Insulators for GS load center\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-00134\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003ePNL-50D-AC-120\/240\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eCircuit breaker, 50 A, 120\/240 VAC, 2 pole, panel mount for GSLC (takes two 3\/4\" spaces)\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e053-17004\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp class=\"tables-table-text\"\u003e\u003cspan\u003ePNL-175-DC\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd colspan=\"7\"\u003e \u003cp class=\"tables-descriptions\"\u003e\u003cspan\u003eCircuit breaker, 175 A, 125 VDC, 1 pole, main DC breaker for GS inverter (2 required per inverter)\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp class=\"tables-item-code\"\u003e\u003cspan\u003e030-04329\u003c\/span\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- \/.block --\u003e\u003c!-- \/.region --\u003e\u003c!-- \/content --\u003e \u003cp\u003e \u003c\/p\u003e","brand":"Outback Power","offers":[{"title":"Default Title","offer_id":67624068087962,"sku":"030-04060","price":2515.51,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/9568\/9626\/files\/Radian-inverter_4a6ebbc1-64f9-415e-bef2-6fa4fc26e6d2.jpg?v=1790783779","url":"https:\/\/coretarps.co.uk\/products\/outback-power-radian-grid-tie-off-grid-inverter-gs8048-8000w-48","provider":"ELMBER TRADE LTD","version":"1.0","type":"link"}