{"product_id":"quincy-2103d12hcb23m-air-compressor","title":"Quincy Air Compressor 4103D12HCB23M QT Max 10 HP 120 Gallon Two Stage 230V 3 Phase","description":"\u003ch2\u003eQuincy 4103D12HCB23M QT MAX 10 HP 120-Gallon Two-Stage Air Compressor, 230V 3-Phase\u003c\/h2\u003e  \u003cp\u003eStorage capacity is easy to shop for. Where the capacity has to physically go is the part that stops installations. This machine answers that: it holds 120 gallons in a \u003cstrong\u003ehorizontal\u003c\/strong\u003e receiver, which puts the whole package at 55\" overall height instead of standing seven feet in the air. If your compressor room has a duct run, a mezzanine floor, a mechanical platform or simply a low ceiling, that difference decides whether the machine goes in at all.\u003c\/p\u003e  \u003cp\u003eWhat sits on top of the tank is Quincy’s QT MAX package: a splash-lubricated cast-iron pump with aluminium heads, driven by belt from a 1,750 RPM industrial motor, with a finned intercooler between the compression stages and an air-cooled aftercooler built into the unit. The pump is rated beyond 50,000 hours. This part number is wound for 230V, 3-phase supply.\u003c\/p\u003e  \u003ch3\u003eWhere a horizontal package goes that a vertical one will not\u003c\/h3\u003e  \u003cp\u003eA vertical 120-gallon receiver is essentially a column. It is efficient with floor area and useless if you do not have the headroom, and it needs clear space above it to pull the pump for service. A horizontal receiver spreads the same volume along the floor instead: 78\" of length, 28\" of width, and a top surface at 55\".\u003c\/p\u003e  \u003cp\u003eIn practice it lives along a wall, behind a bench, under a stair, or on a mezzanine with a low deck-to-deck height. It also puts the pump and the motor at working height rather than overhead, so belt changes and oil checks are a job you can do standing up. Measure the doorway and the route as well as the room — 78\" of rigid crate has to turn the corners between the dock and the final position.\u003c\/p\u003e  \u003ch3\u003eThe cooling package, and why the tank stays dry\u003c\/h3\u003e  \u003cp\u003eTwo-stage compression is done in two steps with cooling in between. The first cylinder raises the air to an intermediate pressure and hands it to the high-efficiency finned intercooler, which strips the heat of compression back out before the second cylinder takes it to working pressure. Rated maximum is 175 PSI.\u003c\/p\u003e  \u003cp\u003eDownstream of the pump, the built-in air-cooled aftercooler drops the discharge temperature again, this time with a fan whose speed is driven by temperature rather than running flat out all day. Cooling the air before it enters the receiver is what makes the moisture condense in the tank, where a drain can deal with it, instead of in the pipework, where it cannot. The automatic electronic tank drain then clears that condensate on a cycle, which is also the practical defence against a receiver rusting from the inside.\u003c\/p\u003e  \u003ch3\u003eWill It Fit?\u003c\/h3\u003e  \u003cul\u003e \u003cli\u003e \u003cstrong\u003eLength:\u003c\/strong\u003e 78\". This is the dimension that governs the installation and the delivery route.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eWidth:\u003c\/strong\u003e 28\", plus whatever clearance you want for belt guard access on the pump side.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHeight:\u003c\/strong\u003e 55\", which is the reason this model exists alongside the vertical ones.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eWeight:\u003c\/strong\u003e 850 lbs dry. Add oil and the working water charge on top of that when you think about the slab.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSupply:\u003c\/strong\u003e 230V, 3-phase. Single-phase service will not run it, and the voltage is set by the motor and starter fitted at the factory, not by a link change on site.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eProtection:\u003c\/strong\u003e the recommended breaker for this model is one for your electrician to size against the run and the local code. We do not publish a figure, because the honest answer depends on your installation.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eConnection:\u003c\/strong\u003e 1\" tank outlet. Run the shop header away from the machine with a fall, and take drops off the top of the header.\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eThe site is yours to prepare.\u003c\/strong\u003e Verifying 230V 3-phase availability at the machine location, the slab condition, the ventilation of the compressor room, and the permitting and inspection of the electrical work are the buyer’s responsibility. Ask us the questions before the freight is booked, not after.\u003c\/p\u003e  \u003ch3\u003eBuilt to be serviced, not just to run\u003c\/h3\u003e  \u003cp\u003eThe pump is splash-lubricated cast iron with aluminium heads — cast iron for the wear surfaces and the mass to absorb heat, aluminium up top where shedding heat matters more than hardness. An oil sight glass makes the level check visual. A low oil cut-off switch shuts the machine down if the level drops far enough to endanger the bearings, and an extra-capacity oil reserve lengthens the interval between checks. The magnetic starter carries thermal overload protection for the motor. None of that is exotic; it is simply the set of features that decides whether a compressor is still running in year eight.\u003c\/p\u003e  \u003ch3\u003ePerfect For\u003c\/h3\u003e  \u003cul\u003e \u003cli\u003e \u003cstrong\u003eShops with a headroom problem\u003c\/strong\u003e — low ceilings, mezzanine decks, or a compressor room under an office floor.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMulti-bay automotive service\u003c\/strong\u003e running impacts, lifts and air tools continuously through a working day.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBody and paint operations\u003c\/strong\u003e, where the aftercooler and the automatic drain do real work on air quality.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBuildings already on 230V 3-phase\u003c\/strong\u003e, the most common three-phase service in independent commercial premises.\u003c\/li\u003e \u003c\/ul\u003e  \u003ch3\u003eWhat is in the Box\u003c\/h3\u003e  \u003cp\u003eYou receive the assembled compressor: the horizontal 120-gallon receiver, the two-stage cast-iron pump, the 10 HP industrial motor, the magnetic starter, the high-efficiency finned intercooler, the built-in air-cooled aftercooler with its temperature-driven variable-speed fan, the automatic electronic tank drain and the low oil cut-off switch. An air dryer is \u003cstrong\u003enot\u003c\/strong\u003e part of this package. Neither is the EWK-4 Maintenance Kit, which has to be bought alongside the compressor if you want the extended warranty term.\u003c\/p\u003e  \u003ch3\u003eSpecifications\u003c\/h3\u003e  \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eHorsepower\u003c\/th\u003e \u003ctd\u003e10 HP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMotor speed\u003c\/th\u003e \u003ctd\u003e1,750 RPM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSupply\u003c\/th\u003e \u003ctd\u003e230V, 3-phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eStarter\u003c\/th\u003e \u003ctd\u003eMagnetic, thermal overload protected\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e  \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eStages\u003c\/th\u003e \u003ctd\u003eTwo-stage, belt driven\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003ePump construction\u003c\/th\u003e \u003ctd\u003eCast iron cylinders, aluminium heads\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOil system\u003c\/th\u003e \u003ctd\u003eSplash lubricated, sight glass, low oil cut-off\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMaximum working pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eHeat management\u003c\/th\u003e \u003ctd\u003eFinned intercooler and built-in air-cooled aftercooler\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e  \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eReceiver\u003c\/th\u003e \u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOutlet\u003c\/th\u003e \u003ctd\u003e1\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOverall length\u003c\/th\u003e \u003ctd\u003e78\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOverall width\u003c\/th\u003e \u003ctd\u003e28\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOverall height\u003c\/th\u003e \u003ctd\u003e55\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eShipping weight\u003c\/th\u003e \u003ctd\u003e850 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e  \u003cp\u003e\u003cem\u003eWe have deliberately left the delivered air volume and the running current off this table. Both figures live in our catalogue without a unit attached to them, and a specification we cannot state with its unit is one we will read off the manufacturer’s data sheet for you instead of publishing.\u003c\/em\u003e\u003c\/p\u003e  \u003ch3\u003eCertification, stated plainly\u003c\/h3\u003e  \u003cp\u003eThe receiver is manufactured to the North American pressure-vessel code and the machine carries a CSA mark. Our records also point at a North American third-party electrical listing, but the entry is ambiguous enough that we will not print the mark. That is deliberate: a badge we got wrong is worse than none. If a specific listing is a condition of your insurance or your local electrical code, contact us and we will confirm what is on the data plate before you commit.\u003c\/p\u003e  \u003ch3\u003eOne thing to confirm with us\u003c\/h3\u003e  \u003cp\u003eThere is a conflict inside our own product data on this model that you should know about. The feature list and the detailed specification block both say an automatic electronic tank drain is fitted; a separate summary field in our catalogue says it is not. We have shown you both rather than quietly picking one. If the electronic drain matters to your installation, ask us to verify it against the as-shipped configuration first.\u003c\/p\u003e  \u003ch3\u003eShipping and delivery\u003c\/h3\u003e \u003cp\u003eFreight only, to the lower 48 states. This is a crated industrial machine on a skid, so plan the unload before it arrives: a forklift with the reach to take the crate off a trailer bed, or a dock at trailer height. Carriers deliver to the truck, not into the building. Terminal pickup is offered and many shops prefer it, because you control the equipment and the timing at both ends.\u003c\/p\u003e \u003cp\u003eA delivery to a residential address is billed with a residential fee, so tell us up front if the address is a house or an outbuilding rather than a commercial receiving point.\u003c\/p\u003e \u003cp\u003eCheck the freight while the driver is still there. Look at the skid, the shrink wrap and the sheet metal, take photographs, and write any damage on the bill of lading before you sign it. Once a clean bill of lading is signed the carrier has your agreement that nothing arrived broken.\u003c\/p\u003e  \u003ch3\u003eWarranty\u003c\/h3\u003e  \u003cp\u003eCoverage is a 1-year factory warranty from Quincy, applied equally to consumer and commercial use. Buying the EWK-4 Maintenance Kit at the same time as the compressor extends that to the 3-year \"No Bull\" warranty, which adds on-site service and labour to the parts cover. Registration of the unit with the manufacturer is required for the extension to stand.\u003c\/p\u003e  \u003cp\u003eHouse rule on any warranty event, and it is the one that most often decides a claim: \u003cstrong\u003ecall us before anything is dismantled.\u003c\/strong\u003e Once a pump has been opened, nobody can establish what failed first, and an opened unit is the most common reason a valid claim gets turned down.\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":49287158300826,"sku":"2020040883","price":5085.5,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/quincy-2103d12hcb23m-air-compressor","provider":"My Store","version":"1.0","type":"link"}