{"product_id":"quincy-253ds80hcb20-air-compressor","title":"Quincy Air Compressor 453DS80HCB20 QT Pro 5 HP 80 Gallon Two Stage 208V 3 Phase","description":"\u003ch2\u003eQuincy 453DS80HCB20 QT Pro — 5 HP, 80-Gallon Two-Stage, Horizontal Tank, 208 Volt Three-Phase\u003c\/h2\u003e \u003cp\u003eThis machine lies down. That is the reason it exists as a separate model, and it is the first thing to check against your building: the horizontal receiver brings the whole assembly to about \u003cstrong\u003e47\"\u003c\/strong\u003e tall, which is low enough to live under a mezzanine, beneath a low garage ceiling, or in a bay where a roller-door track rules out anything upright.\u003c\/p\u003e \u003cp\u003eThe second thing to check is the supply. This is the \u003cstrong\u003e208 Volt, 3-Phase\u003c\/strong\u003e version. Quincy builds the same package for three different three-phase voltages and they are not interchangeable in the field — ordering the wrong one means a motor that will not run correctly on your service, so confirm what is actually at your panel before you buy, not what you assume is there.\u003c\/p\u003e \u003ch3\u003eTwo model codes on one machine\u003c\/h3\u003e \u003cp\u003eWorth knowing before you order parts. Our records carry this unit under two codes: \u003cstrong\u003e453DS80HCB20\u003c\/strong\u003e on the product title and the specification field, and \u003cstrong\u003e253DS80HCB20\u003c\/strong\u003e throughout the manufacturer copy this listing was built from. We are not going to guess which one your dealer, your parts supplier or your existing paperwork uses. If you are matching an installed machine or ordering service parts, ask us to confirm the code in writing first.\u003c\/p\u003e \u003ch3\u003eWhy a horizontal tank changes the job\u003c\/h3\u003e \u003cp\u003eA lying-down receiver is not a compromise, it is a different answer to a different building. It puts the pump, the belt guard, the oil sight glass and the drain at working height instead of over your head, so the weekly checks stop involving a step ladder. It also spreads the mass over a longer footprint, which is easier on an ordinary slab.\u003c\/p\u003e \u003cp\u003eWhat it costs you is floor. This one occupies roughly \u003cstrong\u003e70\"\u003c\/strong\u003e by \u003cstrong\u003e23\"\u003c\/strong\u003e, against the much tighter footprint of the upright version of the same machine. If your constraint is floor space rather than headroom, the vertical model is the one to look at. If your ceiling is the problem, this is.\u003c\/p\u003e \u003cp\u003eEither way the pad must be flat, solid and level. At \u003cstrong\u003e660 lbs\u003c\/strong\u003e on four feet, an uneven floor works the mounts loose over a season and pushes vibration into the building. Levelling the machine is a customer responsibility and it repays the attention many times over.\u003c\/p\u003e \u003ch3\u003eThe pump: two stages, cooled in between\u003c\/h3\u003e \u003cp\u003eThe QT-5 industrial pump is a splash-lubricated, belt-driven, two-stage cast-iron design with an aluminium head. Air is compressed once, run through a high-efficiency finned intercooler, then compressed again — and it is that intercooler that makes the difference you can measure. Cooling the charge between stages is why \u003cstrong\u003e175 PSI\u003c\/strong\u003e is a working pressure here rather than a strained maximum, and why carbon does not build up in the head the way it does on a single-stage pump pushed hard.\u003c\/p\u003e \u003cp\u003eQuincy quotes the delivered air as \u003cstrong\u003e17.2 CFM\u003c\/strong\u003e at \u003cstrong\u003e175 PSI\u003c\/strong\u003e. That is a real, published pair — flow means nothing without the pressure it was measured at, and a compressor compared on flow alone is a compressor compared on nothing.\u003c\/p\u003e \u003cp\u003eTwo build details are worth calling out because they are the ones that decide how the machine ages. The connecting rods are two-piece, which means fewer moving parts to align and a simpler job when the pump is eventually serviced. And the oil reservoir is oversized, which is not about capacity so much as temperature — a larger volume of oil runs cooler and stays in grade longer on a machine that is expected to keep pumping.\u003c\/p\u003e \u003ch3\u003eMotor and protection\u003c\/h3\u003e \u003cp\u003eAn ODP slow-speed motor drives it. Running a pump at low shaft speed is the least glamorous durability decision on a compressor and one of the most effective: less heat, less wear at the rings and bearings, and noticeably less noise in a room people have to work in.\u003c\/p\u003e \u003cp\u003eProtection is factory-fitted rather than something to specify. There is a magnetic starter with thermal overload on the machine when it arrives, low-oil shutdown, and automatic condensate draining, so the routine that most often kills a receiver — nobody remembering to drain it — is handled by the machine rather than by a person.\u003c\/p\u003e \u003cp\u003eOur data does record an amp draw for the 208 Volt build, but conductor and breaker sizing turn on the length of your run and on local code, so give your electrician the load as it is actually defined — 5 HP, 208 Volt, 3-Phase — and let them size the circuit. Ask us and we will confirm the manufacturer's figure in writing.\u003c\/p\u003e \u003ch3\u003ePerfect For\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eLow-ceilinged bays and workshops\u003c\/strong\u003e — the horizontal tank is the reason to choose this model over its upright sibling.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCommercial and industrial buildings on 208 Volt three-phase service\u003c\/strong\u003e, which is the common supply in leased units and newer light-industrial parks.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eShops running several air tools at once\u003c\/strong\u003e — impact work, sanding, blasting, spray equipment.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAnyone who does their own servicing\u003c\/strong\u003e and would rather have the sight glass and drain at waist height than overhead.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhat's in the Box\u003c\/h3\u003e \u003cp\u003eA complete factory-assembled unit: heavy-duty QT-5 two-stage industrial pump, ODP slow-speed motor, high-efficiency finned intercooler, two-piece connecting rods, oversized oil reservoir, oil sight glass, factory-mounted magnetic starter with thermal overload, low-oil shutdown, automatic condensate drain, enclosed belt guard and the horizontal \u003cstrong\u003e80-gallon\u003c\/strong\u003e coded tank with relief valves and a \u003cstrong\u003e3\/4\"\u003c\/strong\u003e outlet.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eNot supplied:\u003c\/strong\u003e aftercooler, air dryer, filtration, regulator or shop plumbing. If your work needs dry air, design that into the line rather than expecting it from the machine.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ch4\u003eSupply and motor\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e \u003ctd\u003e5 HP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e \u003ctd\u003e208 Volt AC, 3-Phase — not field-convertible to another voltage\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e \u003ctd\u003eODP, slow speed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMagnetic starter\u003c\/th\u003e \u003ctd\u003eFactory mounted, with thermal overload\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eBreaker\u003c\/th\u003e \u003ctd\u003eConsult a certified electrician\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003ePump and output\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eType\u003c\/th\u003e \u003ctd\u003eQT-5 two-stage, belt drive, splash lubricated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e \u003ctd\u003eCast iron with aluminium head\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e \u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e \u003ctd\u003eHigh-efficiency finned intercooler\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e \u003ctd\u003eLow-oil shutdown; automatic condensate drain\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003eTank and dimensions\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e \u003ctd\u003e80-gallon, horizontal, coded, with relief valves\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e \u003ctd\u003e3\/4\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e \u003ctd\u003e70\" long × 23\" wide × 47\" high\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e660 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch3\u003eCertification, stated plainly\u003c\/h3\u003e \u003cp\u003eThe receiver is a coded pressure vessel built to the American pressure-vessel standard, and this product's data records UL and CSA recognition on its electrical components. Those are the two claims the data makes, and both are worth having on a tank that works at \u003cstrong\u003e175 PSI\u003c\/strong\u003e.\u003c\/p\u003e \u003cp\u003eNeither of them is a third-party safety listing of the assembled machine as installed in your building. That is a separate document, and some insurers and local inspectors ask for it by name on fixed shop equipment. We would rather tell you that plainly than let a badge on the tank stand in for a listing that was never claimed. If it is a condition of your cover or your inspection, ask us before ordering.\u003c\/p\u003e \u003ch3\u003eShipping and receiving\u003c\/h3\u003e \u003cp\u003eIt travels as palletised freight to the lower 48 states, priced live at checkout for your delivery address rather than from an estimate table.\u003c\/p\u003e \u003cp\u003eHave the unloading sorted first. The carrier brings the pallet to the back of the truck and that is where their job ends, so a dock, a forklift or a pallet jack on flat ground needs to be there. No equipment on site? Terminal pickup is the answer — collect it from the carrier's yard with whatever you like. A home address counts as residential delivery and carries a residential fee.\u003c\/p\u003e \u003cp\u003eThen inspect it in front of the driver. Anything written on the bill of lading before you sign is claimable; anything discovered after a clean signature generally is not. Take photographs of the pallet and the crate, and write down what you see even if the damage looks cosmetic.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eThe unit carries a \u003cstrong\u003e1-Year\u003c\/strong\u003e factory warranty which extends to Quincy's \u003cstrong\u003e3-Year\u003c\/strong\u003e \"No Bull\" warranty. That extension is conditional on Quincy's own terms rather than automatic, so read the warranty handbook linked on this page and confirm what applies to this model before you count on the longer period.\u003c\/p\u003e \u003cp\u003eAnd whatever cover you have, do not take the pump apart to diagnose it. A disassembled pump cannot be assessed for what failed first, and a claim on one is a much harder case to make. Call us, describe the symptom, and let it be looked at whole.\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":49287154958490,"sku":"2020040799","price":2503.9,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/quincy-253ds80hcb20-air-compressor","provider":"My Store","version":"1.0","type":"link"}