{"product_id":"quincy-253ds80hcb23-air-compressor","title":"Quincy Air Compressor 453DS80HCB23 QT Pro 5 HP 80 Gallon Two Stage 230V 3 Phase","description":"\u003ch2\u003eQuincy 453DS80HCB23 QT Pro — 80-Gallon Two-Stage, Horizontal, 230 Volt Three-Phase\u003c\/h2\u003e \u003cp\u003eThere is a trap in this part of the Quincy range and it is worth naming before anything else. The QT Pro \u003cstrong\u003e80-gallon\u003c\/strong\u003e two-stage package is sold as several visually identical machines that differ only in two things: whether the receiver stands up or lies down, and what supply the motor is wound for. This one is the horizontal tank on \u003cstrong\u003e230 Volt, 3-Phase\u003c\/strong\u003e.\u003c\/p\u003e \u003cp\u003eThe voltage is not a switch on the side. It is how the motor is built, and it is the single most common reason one of these sits on a pallet for a fortnight waiting for the right unit. Check the panel that will actually feed it — measured, not assumed, and not remembered from the last tenant — before you order.\u003c\/p\u003e \u003ch3\u003eTwo model codes for the same unit\u003c\/h3\u003e \u003cp\u003eA second thing to settle up front. Two codes are published for this compressor: the title and specification data give \u003cstrong\u003e453DS80HCB23\u003c\/strong\u003e, while the manufacturer copy behind this listing gives \u003cstrong\u003e253DS80HCB23\u003c\/strong\u003e. \u003cstrong\u003eIf you are matching an existing installation or ordering service parts against a code, ask us to confirm it in writing before you commit\u003c\/strong\u003e — we will have Quincy settle it.\u003c\/p\u003e \u003ch3\u003eThe horizontal layout, and who it suits\u003c\/h3\u003e \u003cp\u003eLying the receiver down takes the overall height to about \u003cstrong\u003e47\"\u003c\/strong\u003e and stretches the footprint to roughly \u003cstrong\u003e70\"\u003c\/strong\u003e by \u003cstrong\u003e23\"\u003c\/strong\u003e. That is the trade in one sentence: you spend floor to buy headroom. It suits a bay with a low ceiling, a mezzanine overhead, a door track in the way, or a wall run where a long low machine tucks behind a bench and an upright one would not.\u003c\/p\u003e \u003cp\u003eIt also puts every service point at working height. The sight glass, the belt guard and the drain sit where you can see and reach them, which in practice is the difference between a compressor that gets its weekly check and one that does not.\u003c\/p\u003e \u003cp\u003eSite it on a flat, solid, level pad. \u003cstrong\u003e660 lbs\u003c\/strong\u003e on four feet finds every high spot in a slab, and a machine that rocks will loosen its own mounts and put vibration through the building. Getting the floor right is the buyer's job and it costs nothing but attention.\u003c\/p\u003e \u003ch3\u003eWhat two-stage compression is doing for you\u003c\/h3\u003e \u003cp\u003eAir enters, gets compressed, passes through a high-efficiency finned intercooler, then gets compressed a second time. Cooling between the stages is the whole point: hot air resists compression, so cooling it first is what lets the pump reach \u003cstrong\u003e175 PSI\u003c\/strong\u003e as an everyday working pressure rather than a limit it strains at. It also keeps carbon from baking into the head, which is what shortens valve life on single-stage machines run hard.\u003c\/p\u003e \u003cp\u003eThe published output is \u003cstrong\u003e17.2 CFM\u003c\/strong\u003e at \u003cstrong\u003e175 PSI\u003c\/strong\u003e. Note the pair. A flow figure with no pressure attached to it is not a specification, and comparing two compressors on flow measured at different pressures is comparing nothing at all.\u003c\/p\u003e \u003ch3\u003eDetails that decide the service life\u003c\/h3\u003e \u003cp\u003eThree of them, and none are cosmetic. The connecting rods are two-piece — fewer parts in motion and a straightforward job the day the pump needs attention. The oil reservoir is oversized, which matters for temperature more than capacity: more oil runs cooler and holds its grade longer under continuous work. And the manufacturer states oil carryover under 5 PPM, meaning very little oil mist leaves with the air, which is what you want if the line ever feeds finish work or air tools with tight tolerances.\u003c\/p\u003e \u003cp\u003eThe motor is an ODP slow-speed design. Turning the pump more slowly is an unglamorous way to buy durability and it works — less heat generated, less wear at the rings and bearings, and a machine you can hold a conversation next to.\u003c\/p\u003e \u003ch3\u003eProtection you do not have to specify\u003c\/h3\u003e \u003cp\u003eA factory-mounted magnetic starter with thermal overload comes on the machine, so the contactor and the motor protection are not a separate purchase and a separate mounting job. Low-oil shutdown stops the pump before a lubrication problem becomes a rebuild. An automatic tank drain handles the condensate, which quietly removes the most common cause of a rusted-through receiver: nobody remembering.\u003c\/p\u003e \u003cp\u003eOur data does hold an amp figure for this build, but the conductor and breaker your electrician needs depend on the run length and your local code. Give them the real definition of the load — 5 HP, 230 Volt, 3-Phase — and let them size it. If you want the manufacturer's number for a load calculation, ask and we will send it in writing.\u003c\/p\u003e \u003ch3\u003ePerfect For\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eShops on 230 Volt three-phase\u003c\/strong\u003e, common in older commercial and light-industrial buildings.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow-ceiling installations\u003c\/strong\u003e where an upright 80-gallon receiver simply will not stand up.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eContinuous production work\u003c\/strong\u003e — several tools running at once, or one tool running all day.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eOwners who service their own equipment\u003c\/strong\u003e and want the sight glass and drain at hand height.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhat's in the Box\u003c\/h3\u003e \u003cp\u003eThe compressor complete: heavy-duty QT-5 two-stage industrial pump, cast iron with aluminium head, ODP slow-speed motor, high-efficiency finned intercooler, two-piece connecting rods, oversized oil reservoir, sight glass, factory-mounted magnetic starter with thermal overload, low-oil shutdown, automatic tank drain, enclosed belt guard, and the coded horizontal \u003cstrong\u003e80-gallon\u003c\/strong\u003e receiver with relief valves and a \u003cstrong\u003e3\/4\"\u003c\/strong\u003e outlet.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eNot supplied:\u003c\/strong\u003e aftercooler, air dryer, filtration, regulation, or any pipework. Dry air is a separate design job.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ch4\u003eElectrical supply\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e \u003ctd\u003e5 HP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e \u003ctd\u003e230 Volt AC, 3-Phase — model-specific, not field-convertible\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e \u003ctd\u003eODP, slow speed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e \u003ctd\u003eMagnetic, factory mounted, thermal overload\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eBreaker\u003c\/th\u003e \u003ctd\u003eConsult a certified electrician\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003ePump and air\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eType\u003c\/th\u003e \u003ctd\u003eQT-5 two-stage, belt drive, splash lubricated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e \u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOil carryover\u003c\/th\u003e \u003ctd\u003eUnder 5 PPM, per the manufacturer\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eConnecting rods\u003c\/th\u003e \u003ctd\u003eTwo-piece\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e \u003ctd\u003eHigh-efficiency finned intercooler\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003eReceiver and size\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank\u003c\/th\u003e \u003ctd\u003e80-gallon, horizontal, coded, relief valves fitted\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e \u003ctd\u003e3\/4\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDrain\u003c\/th\u003e \u003ctd\u003eAutomatic condensate drain\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e \u003ctd\u003e70\" × 23\" × 47\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e660 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch3\u003eCertification, stated plainly\u003c\/h3\u003e \u003cp\u003eThe claims this product's data actually makes are two: the receiver is coded to the American pressure-vessel standard and carries relief valves, and the electrical components are UL and CSA recognised. On a vessel holding \u003cstrong\u003e175 PSI\u003c\/strong\u003e the first of those is the one that matters most, and it is a real, checkable claim.\u003c\/p\u003e \u003cp\u003eWhat is not claimed anywhere in the data is an independent safety listing of the finished machine as installed. That is a different piece of paper from a component recognition or a vessel code stamp, and some insurers, fleet policies and local inspectors want it specifically for hard-wired equipment. We will not blur the two. If your cover or your sign-off depends on it, raise it with us before you order.\u003c\/p\u003e \u003ch3\u003eShipping and receiving\u003c\/h3\u003e \u003cp\u003eThis item ships free within the lower 48 states, so there is nothing to add at checkout.\u003c\/p\u003e \u003cp\u003eDecide in advance how it leaves the truck. The driver delivers to the tailgate and no further, so line up a dock, a forklift, or a pallet jack and level ground. If none of that exists at your address, choose terminal pickup and take your own equipment to the carrier's yard. Deliveries to a home address are residential and carry a residential fee — say so at the point of order, not on the day.\u003c\/p\u003e \u003cp\u003eInspect the shipment before you sign anything. Damage recorded on the bill of lading while the driver is standing there can be claimed; damage found after a clean signature usually cannot. Photograph everything and write down what you see, even if you are not certain it matters.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eA \u003cstrong\u003e1-Year\u003c\/strong\u003e factory warranty applies, extending to Quincy's \u003cstrong\u003e3-Year\u003c\/strong\u003e \"No Bull\" warranty. The extension comes with Quincy's own conditions rather than arriving automatically with the machine, so read the warranty handbook linked on this page and check what this model requires before you plan around three years of cover.\u003c\/p\u003e \u003cp\u003eOur own standing advice: if the pump misbehaves, do not open it. A pump that has been apart cannot be assessed for the original cause, and that turns a straightforward warranty claim into an argument. Ring us, describe what it is doing, and let it be examined intact.\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":49287155089562,"sku":"2020040801","price":2503.9,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/quincy-253ds80hcb23-air-compressor","provider":"My Store","version":"1.0","type":"link"}