{"product_id":"quincy-253ds80vcb20-air-compressor","title":"Quincy Air Compressor 453DS80VCB20 QT Pro 5 HP 80 Gallon Two Stage 208V 3 Phase","description":"\u003ch2\u003eQuincy 453DS80VCB20 QT Pro — 5 HP, 80-Gallon Two-Stage, Vertical Tank, 208 Volt Three-Phase\u003c\/h2\u003e \u003cp\u003eThe number worth knowing on this machine is \u003cstrong\u003e1,750 RPM\u003c\/strong\u003e. That is how fast the motor turns the pump, and it is slow — deliberately, expensively slow. Everything a compressor does badly, it does because of heat and speed: rings wear, oil thins, valves carbon up, and the room gets loud. Turning the pump more slowly attacks all four at once, and it is the least fashionable durability decision a manufacturer can make.\u003c\/p\u003e \u003cp\u003eAround that sits a \u003cstrong\u003e5 HP\u003c\/strong\u003e, \u003cstrong\u003e208 Volt\u003c\/strong\u003e, \u003cstrong\u003e3-Phase\u003c\/strong\u003e ODP motor, a two-stage cast-iron pump, and an \u003cstrong\u003e80-gallon\u003c\/strong\u003e receiver standing upright so it gives back floor space rather than headroom.\u003c\/p\u003e \u003ch3\u003eTwo model codes on one unit\u003c\/h3\u003e \u003cp\u003eSettle this before you order parts. Our records carry the machine as \u003cstrong\u003e453DS80VCB20\u003c\/strong\u003e on the product title and specification field, and as \u003cstrong\u003e253DS80VCB20\u003c\/strong\u003e throughout the manufacturer copy this listing was built from. Both mean this compressor. We are not going to guess which one your parts supplier or your existing paperwork expects — ask us to confirm it in writing if you are matching an installed unit.\u003c\/p\u003e \u003ch3\u003eSlow speed, and what it is worth\u003c\/h3\u003e \u003cp\u003eA pump can be made to produce a given volume of air by being large and unhurried or small and frantic. The second is cheaper to build. It is also hotter, noisier, and harder on the parts that are expensive to replace — because heat is what drives oil out of grade and bakes carbon onto valve plates, and valve condition is what quietly decides when a compressor stops being efficient long before it stops running.\u003c\/p\u003e \u003cp\u003eAt \u003cstrong\u003e1,750 RPM\u003c\/strong\u003e this pump runs cool enough to be worth building in cast iron, and quiet enough that people can work near it without shouting. Combined with splash lubrication, an oversized oil reservoir and industrial-class bearings, that is the whole argument for a machine of this weight in a class where lighter, faster units exist.\u003c\/p\u003e \u003ch3\u003eThe two stages, and the cooler between them\u003c\/h3\u003e \u003cp\u003eAir is compressed once, sent through a high-efficiency finned intercooler, and compressed again. That intercooling is not a refinement — it is the mechanism. Hot air resists compression, so cooling the charge mid-cycle is what lets the pump treat \u003cstrong\u003e175 PSI\u003c\/strong\u003e as an everyday working pressure rather than a limit it strains against, and it is what stops carbon accumulating in the head the way it does on a single-stage machine pushed hard.\u003c\/p\u003e \u003cp\u003eQuincy publishes the output as \u003cstrong\u003e17.2 CFM\u003c\/strong\u003e at \u003cstrong\u003e175 PSI\u003c\/strong\u003e. Take the pair together and ignore any comparison that quotes flow without the pressure it was measured at — the two are meaningless apart. The pump also runs a low oil carryover, so very little oil mist leaves with the air, which matters if the line will ever feed finish work.\u003c\/p\u003e \u003cp\u003eThe duty rating is \u003cstrong\u003e100%\u003c\/strong\u003e. In practical terms that means you schedule the work, not the compressor: it is built to keep pumping rather than to be rested between runs.\u003c\/p\u003e \u003ch3\u003eWill it fit?\u003c\/h3\u003e \u003cp\u003eStanding upright, the machine takes about \u003cstrong\u003e37\"\u003c\/strong\u003e by \u003cstrong\u003e24\"\u003c\/strong\u003e of floor and stands \u003cstrong\u003e74\"\u003c\/strong\u003e tall. That is the trade in a sentence — it asks for headroom and gives back floor, which is the right answer in a tight bay and the wrong one under a low mezzanine. Measure the height of the intended corner including shelving, ductwork and any door track above it, and leave reach room around the belt guard, sight glass and drain.\u003c\/p\u003e \u003cp\u003eThe slab matters more on a tall machine than a low one. \u003cstrong\u003e680 lbs\u003c\/strong\u003e standing high on four feet will find every irregularity in a floor, and a unit that rocks slowly loosens its own mounting and puts vibration through the building. A flat, solid, level pad is the buyer's responsibility and it repays the attention.\u003c\/p\u003e \u003cp\u003ePlan the air line as a separate job. The outlet is \u003cstrong\u003e3\/4\"\u003c\/strong\u003e, and there is no aftercooler or air dryer on this machine, so drying, filtration and regulation are items you add to the run.\u003c\/p\u003e \u003ch3\u003eProtection that arrives fitted\u003c\/h3\u003e \u003cp\u003eThe magnetic starter is factory-mounted with thermal overload, so the contactor and the motor protection are not a separate purchase, a separate mounting job and a second electrician's visit. Low-oil shutdown stops the pump before a lubrication problem becomes a rebuild, and automatic condensate draining removes the most common cause of a destroyed receiver — nobody remembering to open a valve.\u003c\/p\u003e \u003cp\u003eOn the supply side, our data does hold a current figure for the 208 Volt build, but conductor and breaker sizing depend on the length of your run and on local code. Give your electrician the load as it is genuinely defined — \u003cstrong\u003e5 HP\u003c\/strong\u003e, \u003cstrong\u003e208 Volt\u003c\/strong\u003e, \u003cstrong\u003e3-Phase\u003c\/strong\u003e — and let them size it. Ask us and we will send the manufacturer's figure in writing for a panel schedule.\u003c\/p\u003e \u003ch3\u003ePerfect For\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eFloor-limited shops\u003c\/strong\u003e that need 80 gallons of storage and cannot spare the length a horizontal receiver takes.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBuildings on 208 Volt three-phase service\u003c\/strong\u003e — the common supply in leased commercial units and newer light-industrial parks.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eNoise-sensitive workspaces\u003c\/strong\u003e where the compressor shares a room with people.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAll-day production work\u003c\/strong\u003e — several tools at once, or one tool running continuously.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhat's in the Box\u003c\/h3\u003e \u003cp\u003eThe complete factory-assembled machine: two-stage splash-lubricated cast-iron belt-drive pump with aluminium head, ODP slow-speed motor, factory-mounted magnetic starter with thermal overload, high-efficiency finned tube intercooler, large balanced cast-iron flywheel, oversized oil reservoir, oil sight glass, enclosed belt guard, low-oil shutdown, automatic condensate drain, and the vertical \u003cstrong\u003e80-gallon\u003c\/strong\u003e coded receiver with relief valves and a \u003cstrong\u003e3\/4\"\u003c\/strong\u003e outlet.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eNot supplied:\u003c\/strong\u003e aftercooler, air dryer, filtration, regulator or pipework.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ch4\u003eMotor and supply\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e \u003ctd\u003e5 HP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eShaft speed\u003c\/th\u003e \u003ctd\u003eApproximately 1,750 RPM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e \u003ctd\u003e208 Volt AC, 3-Phase — wound for this voltage, not field-convertible\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor type\u003c\/th\u003e \u003ctd\u003eODP, slow speed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e \u003ctd\u003eMagnetic, factory mounted, thermal overload\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eBreaker\u003c\/th\u003e \u003ctd\u003eConsult a certified electrician\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003ePump and output\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eType\u003c\/th\u003e \u003ctd\u003eTwo-stage, belt drive, splash lubricated, cast iron with aluminium head\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e \u003ctd\u003e100%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e \u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e \u003ctd\u003eHigh-efficiency finned tube intercooler\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e \u003ctd\u003eLow-oil shutdown; automatic condensate drain\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003eReceiver and dimensions\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank\u003c\/th\u003e \u003ctd\u003e80-gallon, vertical, coded, relief valves fitted\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e \u003ctd\u003e3\/4\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e \u003ctd\u003e37\" × 24\" × 74\" high\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e680 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch3\u003eCertification, stated plainly\u003c\/h3\u003e \u003cp\u003eTwo claims live in this product's data. The receiver is a coded pressure vessel built to the American standard and fitted with relief valves, and the electrical components carry UL and CSA recognition. Both are real and both are checkable.\u003c\/p\u003e \u003cp\u003eNeither is a third-party safety listing of the finished machine as installed in your building. That is a different document from a vessel code stamp or a component recognition, and it is the one some insurers, fleet standards and local inspectors name specifically for fixed, hard-wired equipment. We would rather be clear about the distinction than let a stamp on the tank stand in for something broader. If your cover or your inspection turns on it, ask us before ordering.\u003c\/p\u003e \u003ch3\u003eShipping and receiving\u003c\/h3\u003e \u003cp\u003ePalletised freight to the lower 48 states, free of charge.\u003c\/p\u003e \u003cp\u003eArrange the unloading before you order. The driver brings the pallet to the tailgate and stops there, so a dock, a forklift, or a pallet jack on level ground needs to be waiting. Without any of those, choose terminal pickup and collect from the carrier's yard yourself. A home address is a residential delivery and carries a residential fee.\u003c\/p\u003e \u003cp\u003eThen inspect before signing. Damage written onto the bill of lading with the driver present is claimable; damage found later on a clean signature usually is not. Photograph the pallet and note anything that looks wrong even if you are unsure it matters.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eA \u003cstrong\u003e1-Year\u003c\/strong\u003e factory warranty applies and extends to Quincy's \u003cstrong\u003e3-Year\u003c\/strong\u003e \"No Bull\" warranty. The extension carries Quincy's own conditions rather than arriving automatically with the machine, so read the warranty handbook linked on this page and confirm what this model requires before you count on the longer term.\u003c\/p\u003e \u003cp\u003eOne standing rule from us: a faulty pump stays assembled. Once it has been stripped nobody can establish what failed first, and the claim turns into an argument about opinions rather than evidence. Call us, describe the symptom, and let it be assessed whole.\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":49287155384474,"sku":"453DS80VCB20","price":2503.9,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/quincy-253ds80vcb20-air-compressor","provider":"My Store","version":"1.0","type":"link"}