{"product_id":"quincy-2v41c60vc-air-compressor","title":"Quincy Air Compressor 60 Gallon Two Stage 230V 1 Phase","description":"\u003ch2\u003eQuincy 2V41C60VC QT-54 Pro — 5 HP, 60-Gallon Two-Stage Air Compressor, 230 Volt Single Phase\u003c\/h2\u003e \u003cp\u003eStart with what is \u003cem\u003enot\u003c\/em\u003e in the crate, because it is what decides whether this machine is running next week or waiting on an electrician. The \u003cstrong\u003e2V41C60VC\u003c\/strong\u003e has no magnetic starter fitted and no power cord supplied, Quincy specifies a \u003cstrong\u003e50 Amp\u003c\/strong\u003e breaker for it, and the manufacturer is explicit that installation must be carried out by a qualified technician.\u003c\/p\u003e \u003cp\u003eNone of that is a fault. It is a machine sold to be hard-wired into a shop by someone competent, and it is priced and built accordingly. But it is the single most useful paragraph on this page, and most listings for this model bury it under the feature list.\u003c\/p\u003e \u003ch3\u003eWhat that means in practice\u003c\/h3\u003e \u003cp\u003eBudget for three things alongside the compressor: the switchgear, the wiring, and the electrician's time. A \u003cstrong\u003e5 HP\u003c\/strong\u003e motor on a \u003cstrong\u003e230 Volt\u003c\/strong\u003e, \u003cstrong\u003e1-Phase\u003c\/strong\u003e supply is a substantial single-phase load — the \u003cstrong\u003e50 Amp\u003c\/strong\u003e breaker Quincy recommends tells you that plainly — so check that your panel has both the capacity and a free double-pole slot before you order, not after the pallet arrives.\u003c\/p\u003e \u003cp\u003eA magnetic starter is the item worth discussing with your electrician up front. It switches the motor current through a contactor rather than making a pressure switch do work it was not designed for, and it carries a thermal overload that drops the motor out before a struggling machine cooks its own windings. On a motor this size, most installers will want one. Ask us and we will talk through what suits your installation rather than leaving it to discovery on the day.\u003c\/p\u003e \u003ch3\u003eContinuous duty, and the parts that make it possible\u003c\/h3\u003e \u003cp\u003eThe pump is rated for a \u003cstrong\u003e100%\u003c\/strong\u003e duty cycle: built to keep running rather than to be rested between jobs. What makes that credible is a splash-lubricated cast-iron pump running at low speed, an extra-capacity oil reservoir with low oil pump temperature protection, industrial-grade bearings, and a large balanced cast-iron flywheel angled to move cooling air across the pump. A balanced crankshaft keeps the vibration down, which on a tall machine is as much a mounting question as a comfort one.\u003c\/p\u003e \u003cp\u003eTwo-stage compression is the other half of the story. Air is compressed, passed through a high-efficiency finned tube intercooler, and compressed again. Cooling between the stages is what makes \u003cstrong\u003e175 PSI\u003c\/strong\u003e a working pressure rather than a strained maximum, and it is what stops carbon accumulating in the head — the process that ends valve life early on a single-stage machine worked hard. The head is aluminium for heat dissipation and the reed valves are stainless steel, which is a corrosion decision as much as a flow one.\u003c\/p\u003e \u003cp\u003eOne thing we will not tell you is how many cylinders it has. This product's own copy says one number in the body text and a different one in its feature list, and rather than pick the more plausible of two contradictory sources we would rather say so and let you ask. If the cylinder count matters to your decision, ask us and we will confirm it against a current Quincy sheet before you order.\u003c\/p\u003e \u003ch3\u003eAbout the delivered-air figure\u003c\/h3\u003e \u003cp\u003eSame principle, same reason. Our specification record puts the pump at 15.2 cubic feet per minute rated at \u003cstrong\u003e175 PSI\u003c\/strong\u003e, but that value reaches us in a field whose unit is not established anywhere else in this product's own data. An air system designed around a wrong flow number is an expensive thing to find out late, so if your decision turns on delivered air at a stated pressure, ask us and we will confirm it in writing.\u003c\/p\u003e \u003ch3\u003eWill it fit?\u003c\/h3\u003e \u003cp\u003eThe \u003cstrong\u003e60-gallon\u003c\/strong\u003e receiver stands upright, so the machine takes roughly \u003cstrong\u003e29\"\u003c\/strong\u003e by \u003cstrong\u003e21\"\u003c\/strong\u003e of floor and stands about \u003cstrong\u003e70\"\u003c\/strong\u003e tall — noticeably shorter and tighter than the larger two-stage machines in the range, which is often the deciding factor in a domestic garage or a single-bay shop. Measure to whatever sits above the intended corner, and leave reach room for the gauge, the belt guard and the drain.\u003c\/p\u003e \u003cp\u003eUnderneath it, a flat, solid, level pad. \u003cstrong\u003e475 lbs\u003c\/strong\u003e standing tall on a small footprint magnifies every fault in a slab, and a machine that rocks will loosen its own mounting and hum through the building. Floor preparation is the buyer's responsibility and it is worth doing properly once.\u003c\/p\u003e \u003cp\u003eThe tank outlet is \u003cstrong\u003e1\/2\"\u003c\/strong\u003e, and no air dryer is fitted, so drying, filtration and regulation are separate items in the line. The tank drain is manual — and on this model, with no automatic drain to fall back on, draining it is the routine that decides whether the receiver rusts from the inside.\u003c\/p\u003e \u003ch3\u003ePerfect For\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eSingle-bay shops and serious home garages\u003c\/strong\u003e on 230 Volt single-phase service with panel capacity to spare.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBuyers who already have an electrician\u003c\/strong\u003e, or who want to choose their own starter and switchgear rather than accept a factory fit.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eContinuous work\u003c\/strong\u003e — sanding, blasting, running more than one tool — where a duty-limited machine becomes the bottleneck.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSpaces where a full-size stationary machine is simply too big\u003c\/strong\u003e but a small portable is not enough.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhat's in the Box\u003c\/h3\u003e \u003cp\u003eThe compressor as a factory assembly: two-stage splash-lubricated cast-iron belt-drive pump with aluminium head and stainless-steel reed valves, heavy-duty capacitor-start motor with built-in thermal overload, high-efficiency finned tube intercooler, large balanced cast-iron flywheel, extra-capacity oil reservoir with low oil pump temperature protection, pressure gauge, enclosed belt guard, and the vertical \u003cstrong\u003e60-gallon\u003c\/strong\u003e coded tank with pressure relief valves, manual drain and a \u003cstrong\u003e1\/2\"\u003c\/strong\u003e outlet.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eNot included, and worth reading twice:\u003c\/strong\u003e no magnetic starter, no power cord, no air dryer, no filtration or regulation, no pipework. Installation by a qualified technician is a manufacturer requirement, not a suggestion.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ch4\u003eSupply and electrical\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e \u003ctd\u003e5 HP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e \u003ctd\u003e230 Volt AC, 1-Phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eRecommended breaker\u003c\/th\u003e \u003ctd\u003e50 Amp\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMagnetic starter\u003c\/th\u003e \u003ctd\u003e\u003cstrong\u003eNot fitted\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePower cord\u003c\/th\u003e \u003ctd\u003e \u003cstrong\u003eNot supplied\u003c\/strong\u003e — hard-wired installation by a qualified technician\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor protection\u003c\/th\u003e \u003ctd\u003eCapacitor start with built-in thermal overload\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003ePump\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eType\u003c\/th\u003e \u003ctd\u003eTwo-stage, belt drive, splash lubricated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaterials\u003c\/th\u003e \u003ctd\u003eCast iron with aluminium head; stainless steel reed valves\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e \u003ctd\u003e100%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e \u003ctd\u003eRecorded in our data as 15.2 cubic feet per minute at 175 PSI. Ask us to confirm it in writing.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eCylinder count\u003c\/th\u003e \u003ctd\u003eOur two sources disagree. Ask us and we will confirm it against a current Quincy sheet.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e \u003ctd\u003eLow oil pump temperature protection; extra-capacity reservoir\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch4\u003eTank and dimensions\u003c\/h4\u003e \u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e \u003ctd\u003e60-gallon, vertical, coded, with pressure relief valves\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e \u003ctd\u003e1\/2\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDrain\u003c\/th\u003e \u003ctd\u003eManual — no electronic drain valve\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e \u003ctd\u003e29\" × 21\" × 70\" high\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e475 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch3\u003eCertification, stated plainly\u003c\/h3\u003e \u003cp\u003eThe claims here are specific and we will not stretch them. The receiver is a coded pressure vessel built to the American standard, fitted with pressure relief valves. The motor meets UL and CSA electrical standards. Quincy also states the unit is built in the U.S.A.\u003c\/p\u003e \u003cp\u003eWhat no part of this data claims is a third-party safety listing of the complete machine as installed — and on this model that gap is worth a moment's thought, because the starter and the wiring are your specification rather than Quincy's. Some insurers, fleet standards and local inspectors ask for that listing by name on hard-wired shop equipment. If yours does, raise it with us before you order, and tell your electrician too.\u003c\/p\u003e \u003ch3\u003eShipping and receiving\u003c\/h3\u003e \u003cp\u003ePalletised freight to the lower 48 states. This item ships free, so there is nothing to add at checkout.\u003c\/p\u003e \u003cp\u003eWork out the unload first. A driver's job ends at the tailgate, so a dock, a forklift or a pallet jack on firm level ground needs to be there. If your site has none, take terminal pickup and collect from the carrier with your own equipment. A home address is a residential delivery and carries a residential fee — better agreed at the point of order than debated in a driveway.\u003c\/p\u003e \u003cp\u003eInspect it before you sign. Damage recorded on the bill of lading in front of the driver is claimable; damage found afterwards, on a clean signature, usually is not. Photograph the pallet and the crate and write down anything that looks wrong.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eA \u003cstrong\u003e1-Year\u003c\/strong\u003e factory warranty applies, extending to Quincy's \u003cstrong\u003e3-Year\u003c\/strong\u003e \"No Bull\" warranty. That extension carries Quincy's own conditions rather than arriving automatically with the machine, so read the warranty handbook linked on this page and confirm what this model asks of you before you plan around three years.\u003c\/p\u003e \u003cp\u003eOne rule protects whichever cover you hold: if the pump develops a fault, leave it assembled. Once it has been stripped nobody can determine what failed first, and a claim on a dismantled pump becomes an argument rather than an assessment. Ring us, describe the symptom, and let it be looked at whole.\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":49287156433050,"sku":"2021116649","price":1399.3,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/quincy-2v41c60vc-air-compressor","provider":"My Store","version":"1.0","type":"link"}