{"product_id":"schulz-audaz-mcsv-air-compressor","title":"Schulz Air Compressor Audaz MCSV Two Stage 230V 3 Phase Horizontal","description":"\u003ch2\u003eSchulz Audaz MCSV Horizontal Two-Stage Compressor, 230V 3-Phase\u003c\/h2\u003e \u003cp\u003eMost compressor pages sell you the pump. This one is worth buying on the \u003cstrong\u003eservice schedule\u003c\/strong\u003e. Schulz's IC-TECH® pump design integrates the two compression stages and, on the manufacturer's stated maintenance schedule, doubles the oil change interval to every 300 hours. Over a decade in a working shop that is not a footnote — it is dozens of oil changes that do not happen, each one an hour of a technician's time, a jug of compressor oil, and a machine standing idle while the crankcase drains.\u003c\/p\u003e \u003cp\u003eWhat supports that interval is the rest of the pump: Swedish steel valve plates, CNC-machined internal components, a forced-air cooling cover over the pump, and corrosion-resistant coatings on a machine whose whole job produces water. Underneath it, the specification is a 5 HP, two-stage, solid cast iron pump on an 80-gallon horizontal tank, delivering 20 CFM at 175 PSI on a 230V, 3-Phase supply.\u003c\/p\u003e \u003ch3\u003eWill it fit?\u003c\/h3\u003e \u003cp\u003eThe tank lies down, so this is a long, low machine rather than a tall one: 52\" of length, 48\" of width, and 42\" of height. That height is the useful number if you are siting it beneath a mezzanine, a storage deck, a duct run or a low garage ceiling. Add clearance to all three figures — the cooling cover needs moving air, and the drain and gauges need to be reachable without shifting the machine.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eThe supply is 230V three-phase, and that is a hard requirement, not a preference.\u003c\/strong\u003e Three-phase cannot be created at the panel; the building either has it or it does not. If yours does not, ask us for the single-phase version of this machine rather than trying to make this one work. Amp draw and breaker size are not published here because our specification sheet for the model does not state them — it directs you to a certified electrician, and sizing the circuit, disconnect and wire run is the buyer's responsibility. Have whoever wires it confirm pump rotation on first start, too: a three-phase motor will run happily in the wrong direction if the legs land the wrong way round, and a compressor pump turning backwards does damage rather than work.\u003c\/p\u003e \u003ch3\u003eWhy the maintenance interval is the real cost\u003c\/h3\u003e \u003cp\u003eThe purchase price of a shop compressor is the smallest part of what it costs you. Electricity is the largest, and servicing is the one you notice, because it happens on a Tuesday when the machine is needed. Two design choices on this unit attack that directly.\u003c\/p\u003e \u003cp\u003eThe first is the two-stage layout itself. Compressing in two steps means neither cylinder works as hard, so neither runs as hot, and heat is what ages oil, hardens seals and glazes bores. A cooler pump is a pump whose oil stays serviceable longer — which is precisely what makes a 300-hour interval defensible rather than optimistic.\u003c\/p\u003e \u003cp\u003eThe second is direct coupling. The pump bolts straight to the motor: no belt to glaze and slip, no pulleys to align, no tension to check, no guard to remove first. Belt wear on a shop compressor is insidious, costing output quietly for months before anything actually fails. Deleting the belt deletes the failure and the inspection alike.\u003c\/p\u003e \u003ch3\u003eValves, machining and cooling\u003c\/h3\u003e \u003cp\u003eValve plates are the component that usually gives up first in a hard-worked compressor. They open and shut on every stroke, they run hot, and when they flutter or crack the pump keeps running while quietly losing delivery. Swedish steel is a materials choice aimed squarely at that: better-tempered valve stock holds its shape at temperature and delays the failure.\u003c\/p\u003e \u003cp\u003eCNC-machined internals matter for a related reason. Tighter, more repeatable tolerances mean less blow-by past the rings, which means less of the compressed air leaking back where it came from, which means the pump spends less time running to deliver the same air. The forced-air cooling cover over the pump ties the whole argument together — it keeps head temperature down under continuous duty, which is when this machine is at its most stressed and when a badly cooled pump starts eating itself.\u003c\/p\u003e \u003ch3\u003eStorage pressure and why 175 PSI is the number to look at\u003c\/h3\u003e \u003cp\u003eAn 80-gallon tank charged to 175 PSI stores considerably more usable air than the same tank at a lower cut-out pressure. That reserve is what separates a compressor you barely hear from one that runs almost continuously behind a technician on an impact gun. Combined with a 20 CFM delivery, it is enough for sustained air-tool work by more than one person, or for a single heavy consumer such as a sander used in long passes.\u003c\/p\u003e \u003ch3\u003ePerfect for\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eThree-phase commercial shops with a ceiling constraint\u003c\/strong\u003e — the combination this specific configuration exists to serve.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFleet, municipal and dealership service departments\u003c\/strong\u003e running air most of the working day, where the service interval shows up on a budget line.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFabrication and body shops\u003c\/strong\u003e needing sustained delivery rather than short bursts.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBuyers replacing a tired belt-drive machine\u003c\/strong\u003e and tired of chasing belts.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhat's in the box\u003c\/h3\u003e \u003cp\u003eThe compressor as specified: IC-TECH® two-stage cast iron pump, direct coupled to the motor, on the 80-gallon horizontal ASME tank, with the magnetic starter, pressure gauge and tank drain fitted. Our data records no aftercooler and no air dryer on this unit, so if your work needs dry air, budget for a dryer separately. Hose, fittings, air-line filtration and the electrical installation are not supplied.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e \u003ctd\u003e5 HP, electric\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e \u003ctd\u003e230V, 3-Phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMagnetic starter\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAmp draw \/ breaker\u003c\/th\u003e \u003ctd\u003eConsult a certified electrician\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePump\u003c\/th\u003e \u003ctd\u003eTwo-stage, solid cast iron, direct drive, IC-TECH®\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eLubrication\u003c\/th\u003e \u003ctd\u003eOil lubricated, splash system\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eStated oil change interval\u003c\/th\u003e \u003ctd\u003eEvery 300 hours (manufacturer's schedule)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDelivery\u003c\/th\u003e \u003ctd\u003e20 CFM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank\u003c\/th\u003e \u003ctd\u003e80 gallon, horizontal\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e \u003ctd\u003e1\/2\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eLength\u003c\/th\u003e \u003ctd\u003e52\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWidth\u003c\/th\u003e \u003ctd\u003e48\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e \u003ctd\u003e42\"\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eOne number we are not printing\u003c\/h3\u003e \u003cp\u003eThere is no shipping weight in the table above, and that is deliberate. The weight recorded against this three-phase configuration is substantially lighter than the weight recorded against the otherwise identical single-phase machine — same tank, same pump, same dimensions — and both cannot be right. Since weight is what you plan your unloading around and what freight is rated on, we would rather tell you that than publish a figure we do not trust. \u003cstrong\u003eAsk us before delivery day and we will confirm the crated weight from the manufacturer's documentation.\u003c\/strong\u003e Plan on equipment, not people, either way.\u003c\/p\u003e \u003ch3\u003eCertification, stated plainly\u003c\/h3\u003e \u003cp\u003eASME is the certification our data records for this machine, covering the pressure vessel. It is the only one we will state, because it is the only one claimed in our product data. No further third-party safety listing is being implied for the unit as a whole. Commercial insurers, institutional facilities and some local jurisdictions do impose listing requirements in writing; if that is your situation, ask us before ordering and we will confirm what is printed on the data plate rather than leave you to assume.\u003c\/p\u003e \u003ch3\u003eShipping and delivery\u003c\/h3\u003e \u003cp\u003eFreight only, to the lower 48 states, priced live at checkout against your real delivery address instead of estimated on this page. You will need a forklift or a dock, or you can collect from the carrier's terminal, which is frequently the simpler route for a machine this size. Residential delivery carries a residential fee, shown at checkout before you pay. Pickup is available at Acworth, GA.\u003c\/p\u003e \u003cp\u003eInspect the shipment before signing for it. Put any damage — dented tank, bent cooling cover, crushed crating, missing carton — in writing on the delivery receipt at the time of delivery, and photograph it while the driver is present. Signing a clean receipt and calling afterwards is the sequence that loses claims.\u003c\/p\u003e \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eCoverage is 1 year, consumer and commercial, on the manufacturer's stated terms. Do not disassemble the pump, motor, starter or pressure switch before a claim has been opened; a stripped machine is routinely refused regardless of how correct the diagnosis was. Call, text or chat with us on 866-774-7743 first and we will tell you what the manufacturer needs to see.\u003c\/p\u003e","brand":"Schulz of America","offers":[{"title":"Default Title","offer_id":49287162626202,"sku":"932.9371-0","price":1470.0,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/schulz-audaz-mcsv-air-compressor","provider":"My Store","version":"1.0","type":"link"}