{"product_id":"schulz-l-series-7-5hp-air-compressor","title":"Schulz Air Compressor 7580VL30X-1 Two Stage 230V 1 Phase","description":"\u003ch2\u003eSchulz 7580VL30X-1: 7.5 HP of two-stage air on an ordinary single-phase supply\u003c\/h2\u003e\u003cp\u003eThe reason to look at this machine rather than the smaller L-Series units around it is the motor. It is a \u003cstrong\u003e7.5 HP\u003c\/strong\u003e two-stage compressor that runs on \u003cstrong\u003e230V 1-phase\u003c\/strong\u003e power. Most two-stage pumps in this size class expect a three-phase service, which for an independent shop or a serious home workshop is a conversation with the utility company rather than an afternoon with an electrician. This one is not, and that single fact is what usually decides the purchase.\u003c\/p\u003e\u003cp\u003eThe second thing worth knowing sits on the specification sheet and nowhere in the manufacturer's sales copy: this unit is listed with an \u003cstrong\u003eafter-cooler fitted as standard\u003c\/strong\u003e. On the rest of the L-Series and V-Series pages in this range that line reads No. It matters more than it sounds, and there is a section on it below.\u003c\/p\u003e\u003ch3\u003eWhy the single-phase rating is the headline\u003c\/h3\u003e\u003cp\u003eAir demand is easy to underestimate. One air ratchet is nothing; two technicians on a die grinder and a sander with a blow gun going is a different machine entirely. The usual upgrade path out of a small garage compressor runs straight into an electrical wall, because the motors that feed that kind of demand are normally sold three-phase only. A 230V 1-phase circuit, by contrast, is the same class of supply that already feeds a welder or a two-post lift power unit — a wiring job rather than a service upgrade, which is the difference between installing a compressor this month and budgeting for one next year.\u003c\/p\u003e\u003cp\u003eSchulz does not publish an amp draw or a recommended breaker size for this model. Both fields on its own data sheet read \u003cem\u003econsult a certified electrician\u003c\/em\u003e, and that is the honest answer: the correct breaker depends on the run length, the conductor, the panel and your local code. Do not size it from a number on a web page, ours included.\u003c\/p\u003e\u003ch3\u003eThe after-cooler, and what it actually does for you\u003c\/h3\u003e\u003cp\u003eAir leaves a two-stage pump hot, and hot air holds water vapour. As it cools in the tank and then in your pipework, that vapour condenses — which is why shops blow water through spray guns and watch air tools rust from the inside.\u003c\/p\u003e\u003cp\u003eAn after-cooler sits between pump and tank and drops the discharge temperature before the air is stored, so more moisture falls out at the tank where a drain deals with it, and less travels down the line to the tool. It is not a dryer and does not replace one; this unit's specification lists no air dryer. What it does is move the condensation problem to the one place in the system designed to collect it, which for finishing work or anything air-fed is worth the difference on its own.\u003c\/p\u003e\u003ch3\u003eWill It Fit?\u003c\/h3\u003e\u003cp\u003eThis is a vertical machine, so it buys floor space with height. Check all four of these against your building before you order.\u003c\/p\u003e\u003cul\u003e \u003cli\u003e \u003cstrong\u003eFloor footprint:\u003c\/strong\u003e 33.8 inches long by 25.2 inches wide. That is roughly the plan area of a domestic washing machine, but see the weight below before you assume it goes anywhere.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHeight:\u003c\/strong\u003e 78.7 inches. Measure to the lowest obstruction over the intended spot, not to the roof apex — a garage door track, a light fitting or a duct run is what usually stops it. You also need working room above for filter and belt access.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eWeight:\u003c\/strong\u003e 600 lbs on that small footprint, which is a concentrated load. Schulz publishes no minimum floor thickness or concrete rating for this model. A sound shop slab is normally fine; a wooden mezzanine or a thin residential garage pad deserves a look before delivery day, not after.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePower:\u003c\/strong\u003e 230V, 1-phase, with a mounted and prewired magnetic starter, so the electrician terminates a supply rather than building a control panel.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003eConfirming the ceiling, the floor and the circuit is the buyer's responsibility. A compressor that does not fit the room, or that the panel cannot feed, is not a warranty matter.\u003c\/p\u003e\u003ch3\u003eThe L-Series pump: cast iron, low RPM, deep fins\u003c\/h3\u003e\u003cp\u003eThe pump decides whether this is a ten-year machine or a three-year one, and the L-Series is built around keeping it cool and slow. The block is solid cast iron with an in-line cylinder layout and deeper cooling fins than the entry-grade aluminium pumps this buyer is usually shown. Iron conducts heat away and damps vibration; fins put that heat into the air. A cooler pump oxidises its oil more slowly, and clean oil is most of what bearing life comes down to.\u003c\/p\u003e\u003cp\u003eUnderneath that are oversized main bearings and a double-supported crankshaft, with Swedish steel valves and CNC-machined components. The crankshaft support is the detail worth understanding: a shaft carried at both ends deflects less under load than one carried at one end, so bearings and rings see less side loading every revolution. Drive is by notched belts inside an enclosed guard, splash lubricated, with a sight glass on the crankcase — and no low-oil shut-off, which makes checking that glass part of your routine rather than a convenience.\u003c\/p\u003e\u003ch3\u003ePerfect For\u003c\/h3\u003e\u003cul\u003e \u003cli\u003e \u003cstrong\u003eThe independent service shop\u003c\/strong\u003e that has outgrown a single-stage compressor and cannot justify a three-phase service upgrade.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eTyre and general repair bays\u003c\/strong\u003e running impact tools and a lift together, where recovery time between jobs costs money.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eThe serious home or hobby workshop\u003c\/strong\u003e with 230V already run for a welder or a lift — especially for blasting or finishing, the demands that punish an undersized machine.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLight manufacturing and fabrication\u003c\/strong\u003e needing a dependable supply at working pressure rather than a peak figure on a box.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eWhat Is Fitted and Included\u003c\/h3\u003e\u003cul\u003e \u003cli\u003eWEG electric motor, 7.5 HP\u003c\/li\u003e \u003cli\u003eL-Series solid cast iron two-stage pump, belt driven\u003c\/li\u003e \u003cli\u003eAfter-cooler\u003c\/li\u003e \u003cli\u003eMounted and prewired magnetic starter\u003c\/li\u003e \u003cli\u003eOversized main bearings and Swedish steel valves\u003c\/li\u003e \u003cli\u003eCNC-machined components\u003c\/li\u003e \u003cli\u003eNotched belts with an enclosed belt guard\u003c\/li\u003e \u003cli\u003ePowder-coated components\u003c\/li\u003e \u003cli\u003e80-gallon vertical air tank with a safety valve and a 1\/2-inch outlet\u003c\/li\u003e \u003cli\u003ePressure gauge and oil sight glass\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ch4\u003eMotor and power\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e \u003ctd\u003e7.5 HP, WEG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e \u003ctd\u003e230V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e \u003ctd\u003e1-phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e \u003ctd\u003eMagnetic, mounted and prewired\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAmp draw \/ breaker\u003c\/th\u003e \u003ctd\u003eConsult a certified electrician\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003ePump\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eType\u003c\/th\u003e \u003ctd\u003eTwo-stage, belt drive\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e \u003ctd\u003eSolid cast iron\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eLubrication\u003c\/th\u003e \u003ctd\u003eOil lubricated, splash system, sight glass\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAfter-cooler\u003c\/th\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eLow-oil shut-off\u003c\/th\u003e \u003ctd\u003eNo\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eTank, size and weight\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank\u003c\/th\u003e \u003ctd\u003e80-gallon, vertical\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e \u003ctd\u003e1\/2-inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eElectronic drain valve\u003c\/th\u003e \u003ctd\u003eNo\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAir dryer\u003c\/th\u003e \u003ctd\u003eNo\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eLength by width\u003c\/th\u003e \u003ctd\u003e33.8 inches by 25.2 inches\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e \u003ctd\u003e78.7 inches\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e600 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCertification, stated plainly\u003c\/h3\u003e\u003cp\u003eThe data sheet for this compressor lists one certification: ASME, covering the air tank and the safety valve. That is a pressure-vessel standard and it is the one that matters most on a machine storing 80 gallons of air at working pressure, because the tank is the component whose failure is not recoverable.\u003c\/p\u003e\u003cp\u003eBe precise about what it does not cover: a pressure-vessel certification is not an electrical safety listing, and not a third-party approval of the machine as a whole. If your insurer or local inspector requires a specific electrical listing on fixed shop equipment, ask us and we will confirm in writing what this unit carries before you order.\u003c\/p\u003e\u003ch3\u003eShipping and Delivery\u003c\/h3\u003e\u003cp\u003eThis compressor ships by freight truck within the lower 48 states. Freight is quoted live at checkout for your address, so the figure you see is current rather than a printed estimate.\u003c\/p\u003e\u003cp\u003ePlan the unload before the truck arrives. A crated 600 lb machine is a forklift or pallet-jack job, not a two-person lift. If you have no dock or forklift, take terminal pickup and collect with a trailer, or choose residential delivery, which carries a fee at checkout. Inspect the crate with the driver, and note any damage on the bill of lading before you sign it — a signed clean receipt makes a freight claim very difficult afterwards.\u003c\/p\u003e\u003cp\u003eSchulz collection is also available from Acworth, GA. Call, text or chat if you want to arrange it, or if you would like the dimensions checked against your doorway first: 866-774-7743.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cp\u003eSchulz covers this unit for 1 year, with the pump carried for 2 years. Register and keep your proof of purchase, and keep a note of the commissioning date.\u003c\/p\u003e\u003cp\u003eOne practical warning that applies to every compressor: do not disassemble the pump, the motor or the starter before a claim is raised. An opened unit is normally treated as no longer eligible, however well intentioned the diagnosis was. Call us first and we will start the claim with the manufacturer.\u003c\/p\u003e","brand":"Schulz of America","offers":[{"title":"Default Title","offer_id":49287163248794,"sku":"932.9335-0","price":2563.68,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/schulz-l-series-7-5hp-air-compressor","provider":"My Store","version":"1.0","type":"link"}