{"product_id":"schulz-srp-4008-air-compressor","title":"Schulz Air Compressor SRP 4008 Dynamic Rotary Screw","description":"\u003ch2\u003eSchulz SRP 4008 Dynamic Rotary Screw Air Compressor\u003c\/h2\u003e \u003cp\u003eThe SRP 4008 Dynamic solves two problems that usually force a shop into a separate compressor room. It runs at a continuous 100% duty cycle, and it does so from inside a sound-attenuated cabinet rated at 69 dB(A). The second figure is the one worth pausing on. A screw compressor that can run all day is not much help if it has to live behind a wall you have not built yet, and the enclosure is what lets this machine sit in the same space as the people drawing air from it.\u003c\/p\u003e \u003cp\u003eThe other defining decision is the 2-in-1 layout. The rotary air end and the 60-gallon horizontal receiver are a single tank-mounted assembly rather than two pieces of equipment plumbed together on site. The complete unit occupies one footprint of 49.4\" by 23.6\" and stands 53.5\" tall. It is a 7.5 HP machine on 208-230V three-phase power, producing 25 CFM at 125 PSI.\u003c\/p\u003e \u003ch3\u003eDuty cycle is the specification that changes what your shop can do\u003c\/h3\u003e \u003cp\u003eA reciprocating compressor is sized around rest. It builds pressure, shuts off, cools, and starts again, and its published output assumes it spends a meaningful part of every hour doing nothing. Push past that and the pump runs hot, carries oil into the line, and shortens its own life. A rotary screw air end has no reciprocating mass and no valve train slamming through the same cycle, so a 100% duty cycle rating is not a marketing figure. It means the machine is designed to be running when you look at it, all day, and that the 25 CFM at 125 PSI figure is what you get continuously rather than in bursts.\u003c\/p\u003e \u003cp\u003eThat matters most for the work that never lets a compressor catch up: media blasting, plasma cutting, sanding a panel with a DA, running two or three techs on impact guns during a busy morning. Those are the jobs where a piston unit that looks adequate on paper starts falling behind by mid-afternoon.\u003c\/p\u003e \u003ch3\u003eThe cabinet, and why 69 dB(A) is a siting decision\u003c\/h3\u003e \u003cp\u003eSound attenuation is treated as a comfort feature and it is really a floor-plan feature. At 69 dB(A) the SRP 4008 Dynamic does not have to be exiled to an outbuilding, which means shorter air lines, fewer fittings, less pressure drop, and no separate slab to pour. Schulz also rates the unit to operate in ambient temperatures up to 113 °F, so a corner of the shop that gets hot in July is not automatically disqualified. Give the cabinet clear air on all sides and keep its intake away from grinding dust and paint overspray.\u003c\/p\u003e \u003ch3\u003eOil-injected air end, belt drive, and a controller that tells you what is happening\u003c\/h3\u003e \u003cp\u003eThe air end is oil-injected and belt-driven. Oil injection does three jobs inside a screw compressor at once: it seals the clearance between the rotors, carries away the heat of compression, and lubricates the bearings, which is why a screw unit can hold a continuous rating that a splash-lubricated piston pump cannot. The belt drive keeps the air end and motor as separate serviceable assemblies.\u003c\/p\u003e \u003cp\u003ePower comes from a 7.5 HP TEFC IP55 electric motor on 208-230V three-phase supply. TEFC means totally enclosed and fan-cooled, and the IP55 rating describes how well sealed the enclosure is against dust and water jets. In a shop with airborne abrasive that is the difference between a motor that survives and one that ingests grit. Starting is handled by automatic starters with phase and sequence failure detection, so the machine refuses to run on a miswired or single-phased supply instead of quietly cooking its own windings.\u003c\/p\u003e \u003cp\u003eOperation is supervised by a 24V microprocessor controller. It gives constant readings rather than a pressure gauge and a guess, its operating parameters are adjustable, and when something is wrong it tells you which thing. On a machine expected to run unattended, that is the difference between a service call and a five-minute fix.\u003c\/p\u003e \u003ch3\u003eWill it fit, and what does it need from you?\u003c\/h3\u003e \u003cp\u003eThe unit measures 49.4\" long by 23.6\" wide and 53.5\" high, and it weighs 500 lbs. Plan the footprint plus working clearance for panel access and airflow, and remember that a 500 lb machine on a tank-mounted frame is not something two people slide across a floor.\u003c\/p\u003e \u003cp\u003ePower is 208-230V three phase. Schulz does not publish an amp draw or a recommended breaker for this model and instead directs the installation to a certified electrician, and we pass that on exactly as written rather than guessing a circuit size for you. Confirming that three-phase service is available at your building, and that the branch circuit and disconnect are correctly sized, is the buyer's responsibility. If your shop has only single-phase service, this is not the model to order.\u003c\/p\u003e \u003ch3\u003ePerfect for\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eIndependent repair shops\u003c\/strong\u003e running several bays and several air tools at once, where a piston compressor is already struggling to keep up.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBody and paint shops\u003c\/strong\u003e where sanders and blasters demand continuous air rather than intermittent bursts.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFabrication and welding shops\u003c\/strong\u003e using plasma cutters, which are unforgiving of pressure sag.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSmall production and packaging lines\u003c\/strong\u003e that run air-operated equipment through a full shift.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAny shop that has run out of room\u003c\/strong\u003e for a separate compressor enclosure and needs the machine on the floor with everything else.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eWhat is in the box\u003c\/h3\u003e \u003cp\u003eThe SRP 4008 Dynamic ships as a complete 2-in-1 assembly: the rotary air end and drive motor, the sound-attenuated cabinet, the 24V microprocessor controller, the automatic starter with phase and sequence failure detection, an air filter, and the 60-gallon horizontal air receiver with an oil sight glass and a 1\/2\" tank outlet. The listing does not include an air dryer or an electronic drain valve, and no air line, disconnect or electrical hookup is supplied.\u003c\/p\u003e \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003cthead\u003e\u003ctr\u003e \u003cth\u003eAir end\u003c\/th\u003e \u003cth\u003e\u003c\/th\u003e \u003c\/tr\u003e\u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eType\u003c\/td\u003e \u003ctd\u003eRotary, oil-injected, belt drive\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOutput\u003c\/td\u003e \u003ctd\u003e25 CFM at 125 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaximum pressure\u003c\/td\u003e \u003ctd\u003e125 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDuty cycle\u003c\/td\u003e \u003ctd\u003e100%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLubrication\u003c\/td\u003e \u003ctd\u003eOil lubricated, oil sight glass\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003cthead\u003e\u003ctr\u003e \u003cth\u003eMotor and control\u003c\/th\u003e \u003cth\u003e\u003c\/th\u003e \u003c\/tr\u003e\u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eMotor\u003c\/td\u003e \u003ctd\u003e7.5 HP TEFC IP55 electric\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSupply\u003c\/td\u003e \u003ctd\u003e208-230V, 3 Phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eController\u003c\/td\u003e \u003ctd\u003e24V microprocessor\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStarter\u003c\/td\u003e \u003ctd\u003eAutomatic, phase and sequence failure detection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAmp draw and breaker\u003c\/td\u003e \u003ctd\u003eConsult a certified electrician\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSound level\u003c\/td\u003e \u003ctd\u003e69 dB(A)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003cthead\u003e\u003ctr\u003e \u003cth\u003eTank and dimensions\u003c\/th\u003e \u003cth\u003e\u003c\/th\u003e \u003c\/tr\u003e\u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eReceiver\u003c\/td\u003e \u003ctd\u003e60-gallon horizontal, tank mounted\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTank outlet\u003c\/td\u003e \u003ctd\u003e1\/2\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLength\u003c\/td\u003e \u003ctd\u003e49.4\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWidth\u003c\/td\u003e \u003ctd\u003e23.6\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e53.5\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e500 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaximum ambient\u003c\/td\u003e \u003ctd\u003e113 °F\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eRatings, stated plainly\u003c\/h3\u003e \u003cp\u003eThe 60-gallon horizontal air receiver is an ASME-rated vessel, which is the pressure-vessel standard most jurisdictions and most insurers expect to see on a shop air tank. That rating covers the tank. It is not the same document as a North American third-party electrical safety listing for the complete assembly, and it should not be read as one. Schulz does not publish such a listing for this model in the data we hold. If your insurer, your local inspector or a plant standard requires a nationally recognized testing laboratory mark on the whole machine, verify that requirement before you order rather than after the freight arrives. We would rather tell you now.\u003c\/p\u003e \u003ch3\u003eShipping and delivery\u003c\/h3\u003e \u003cp\u003eThis compressor ships by freight to the lower 48 states. Delivery is curbside: the driver brings the shipment to the truck, and unloading is the receiver's responsibility. Most buyers use a forklift, a loading dock, or arrange to collect from the carrier's terminal. Delivery to a residential address carries a residential fee, quoted at checkout. Pickup for Schulz equipment is available in Acworth, GA.\u003c\/p\u003e \u003cp\u003eInspect the shipment before you sign for it. Walk around the crate, look for punctures, crushed corners and shifted banding, and write any damage you find on the bill of lading before the driver leaves. A signature on a clean bill of lading is the carrier's evidence that the machine arrived intact, and it is very difficult to unwind afterwards. Photographs taken at the truck cost nothing and settle claims.\u003c\/p\u003e \u003ch3\u003eWarranty and support\u003c\/h3\u003e \u003cp\u003eSchulz covers this unit with a 12-month warranty; the specification sheet records the consumer and commercial warranty each as 1 year. Do not disassemble the air end, the motor or the controller before a claim is opened. A unit that has been opened is extremely difficult to warranty, and the first question any manufacturer asks is whether the failed part is still as it failed. Call, text or chat with us before you take anything apart. Our phone number is 866-774-7743.\u003c\/p\u003e","brand":"Schulz of America","offers":[{"title":"Default Title","offer_id":49287187955866,"sku":"970.4075-0","price":5604.48,"currency_code":"GBP","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/schulz-srp-4008-air-compressor","provider":"My Store","version":"1.0","type":"link"}