{"product_id":"schulz-v-series-5hp-air-compressor","title":"Schulz Air Compressor V Series 5 HP 80 Gallon Two Stage 208V 3 Phase","description":"\u003ch2\u003eSchulz V-Series 5 HP, 80-Gallon Two-Stage — wired for 208V 3-phase\u003c\/h2\u003e\u003cp\u003eThis listing exists because of one number on the motor plate: \u003cstrong\u003e208V\u003c\/strong\u003e. It is the version of the 5 HP V-Series built for a 208V 3-phase service, which is the supply a great many commercial units, strip-mall bays, multi-tenant industrial buildings and newer light-industrial premises actually have — as opposed to the higher three-phase supplies used in heavy industry, or the single-phase power in a domestic garage.\u003c\/p\u003e\u003cp\u003eGet that right and the rest is a well-proven machine: a WEG motor, a solid cast iron two-stage pump rated to \u003cstrong\u003e175 PSI\u003c\/strong\u003e, an 80-gallon ASME receiver and a magnetic starter mounted and prewired at the factory. Get it wrong and you own a compressor your building cannot run.\u003c\/p\u003e\u003ch3\u003eWhy voltage is the one specification you cannot fix later\u003c\/h3\u003e\u003cp\u003eAlmost everything else about a compressor purchase is recoverable. Too small a tank, add a receiver. Wrong fitting, buy an adaptor. Too long a pipe run, re-plumb it. Voltage is not like that. A three-phase motor is wound for the supply it was ordered for, and a mismatch is not a matter of degree — run on the wrong supply it draws the wrong current, heats up and takes its insulation with it. The fix is a transformer or a new motor, on top of a machine you have already paid freight on.\u003c\/p\u003e\u003cp\u003eSo before you order, do this: have your electrician measure line-to-line at the panel that will feed the compressor, and confirm it is a 208V 3-phase service rather than assuming from the building age or the label on another machine. It takes five minutes and it is the difference between a delivery and a dispute.\u003c\/p\u003e\u003cp\u003eIf your measurement comes back as something other than 208V, do not order this variant. Contact us and we will point you at the correct one — Schulz builds this V-Series pump behind several different motors, and we would much rather have the conversation before the freight than after it.\u003c\/p\u003e\u003ch3\u003eA note on the model number\u003c\/h3\u003e\u003cp\u003eThis listing is published without a model code in its title, and the specification data we hold for it records the model as the configuration description rather than a part number. We have not invented one. If you need the exact Schulz part number for a purchase order, a service parts list or a facilities asset register, ask us and we will confirm it in writing.\u003c\/p\u003e\u003ch3\u003eWhat a 3-phase motor does for a compressor\u003c\/h3\u003e\u003cp\u003eThree-phase power arrives as three supplies offset in time, so the motor is always being pushed by one of them. Torque is continuous instead of pulsing, and the motor needs no start capacitor and no centrifugal starting switch — two of the parts most likely to fail on a single-phase compressor, generally on a cold morning when thick oil and tank pressure make the first start of the day the hardest one.\u003c\/p\u003e\u003cp\u003eThe current is also shared across three conductors rather than two, so the same work is done with less current in each. That means less heating in the windings under a long duty cycle, less voltage drop down a long run, and a motor that shrugs off the kind of repeated starting a busy shop puts a compressor through.\u003c\/p\u003e\u003ch3\u003eWill It Fit?\u003c\/h3\u003e\u003cul\u003e \u003cli\u003e \u003cstrong\u003eFloor:\u003c\/strong\u003e 56 inches by 23 inches — long and narrow, so it wants a wall rather than a corner. Leave working room at the belt guard and clear access to the tank drain.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHeight:\u003c\/strong\u003e 42 inches. Low enough to live under a rack, a mezzanine or a roller-door track.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eWeight:\u003c\/strong\u003e 479 lbs. Schulz publishes no slab thickness or concrete rating for this model and none is invented here; on a normal commercial floor it is not a consideration.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePower:\u003c\/strong\u003e 208V, 3-phase. The amp draw and breaker fields on the data sheet both read \u003cem\u003econsult a certified electrician\u003c\/em\u003e — correct, because the breaker depends on the conductor, the run and your local code, and no product page can size it responsibly.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePlumbing:\u003c\/strong\u003e 1\/2-inch tank outlet. The downstream pipe, not the outlet, is what usually limits pressure at the tool.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003eConfirming the space, the floor and the supply before ordering is the buyer's responsibility.\u003c\/p\u003e\u003ch3\u003eTwo stages, and what the second one is for\u003c\/h3\u003e\u003cp\u003eA single-stage pump compresses air once and is done. A two-stage pump compresses it in a large cylinder, passes it to a smaller one, and compresses it again — which is how it reaches a working pressure a single-stage machine cannot, and does it with less heat per stage than doing the whole job in one go.\u003c\/p\u003e\u003cp\u003eFor a buyer, the payoff is stored energy. High pressure in a large receiver gives a wide band between the pressure that starts the motor and the pressure that stops it, so the machine runs in long, efficient stretches instead of switching on and off every few minutes. Short-cycling is what wears out contactors, motors and pumps; volume and pressure together are the cure.\u003c\/p\u003e\u003cp\u003eThe pump itself is solid cast iron with its cylinders splayed apart for airflow and deep cooling fins, running oversized main bearings, Swedish steel valves and CNC-machined components, belt driven inside an enclosed guard. Lubrication is splash with a sight glass and no low-oil cut-out, so checking the oil is on your list rather than the machine's. The sheet lists no after-cooler and no air dryer.\u003c\/p\u003e\u003ch3\u003ePerfect For\u003c\/h3\u003e\u003cul\u003e \u003cli\u003e \u003cstrong\u003eLeased commercial and light-industrial units\u003c\/strong\u003e whose service is 208V 3-phase, which is where this variant earns its place.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eMulti-bay service shops\u003c\/strong\u003e running impact tools, tyre machines and blow guns at the same time.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBody and paint shops\u003c\/strong\u003e where the compressor runs most of the day and a cool-running three-phase motor is worth having.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLight manufacturing and assembly\u003c\/strong\u003e needing a dependable working pressure rather than an impressive peak number.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eWhat Is Fitted\u003c\/h3\u003e\u003cul\u003e \u003cli\u003eWEG electric motor, 5 HP, 3-phase\u003c\/li\u003e \u003cli\u003eV-Series solid cast iron two-stage pump, belt driven\u003c\/li\u003e \u003cli\u003eMagnetic starter, mounted and prewired\u003c\/li\u003e \u003cli\u003eOversized main bearings and Swedish steel valves\u003c\/li\u003e \u003cli\u003eCNC-machined components\u003c\/li\u003e \u003cli\u003eNotched belts inside an enclosed belt guard\u003c\/li\u003e \u003cli\u003ePowder-coated components\u003c\/li\u003e \u003cli\u003e80-gallon ASME air receiver with safety valve and a 1\/2-inch outlet\u003c\/li\u003e \u003cli\u003ePressure gauge and oil sight glass\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ch4\u003eMotor and power\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e \u003ctd\u003e5 HP, WEG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e \u003ctd\u003e208V AC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e \u003ctd\u003e3-phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e \u003ctd\u003eMagnetic, mounted and prewired\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAmp draw \/ breaker\u003c\/th\u003e \u003ctd\u003eConsult a certified electrician\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003ePump\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eType\u003c\/th\u003e \u003ctd\u003eTwo-stage, belt drive\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e \u003ctd\u003eSolid cast iron\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eLubrication\u003c\/th\u003e \u003ctd\u003eOil lubricated, splash, sight glass\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAfter-cooler \/ air dryer\u003c\/th\u003e \u003ctd\u003eNo \/ No\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eTank and dimensions\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank\u003c\/th\u003e \u003ctd\u003e80-gallon, horizontal\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e \u003ctd\u003e1\/2-inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eLength\u003c\/th\u003e \u003ctd\u003e56 inches\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWidth\u003c\/th\u003e \u003ctd\u003e23 inches\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e \u003ctd\u003e42 inches\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e479 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCertification, stated plainly\u003c\/h3\u003e\u003cp\u003eThe certification recorded for this compressor is ASME, covering the air receiver and safety valve — a pressure-vessel standard, and the one worth insisting on for the part of the machine that stores the energy.\u003c\/p\u003e\u003cp\u003eIt is worth naming the boundary rather than letting one certification stand in for several: ASME is not an electrical safety listing and does not certify the machine as an assembly. On a commercial installation an insurer or a facilities standard may ask specifically about listed fixed electrical equipment. Ask us first and we will confirm in writing what this unit carries.\u003c\/p\u003e\u003ch3\u003eShipping and Delivery\u003c\/h3\u003e\u003cp\u003eThis machine ships by freight to the lower 48 states, priced live at checkout for your address.\u003c\/p\u003e\u003cp\u003ePlan the unload before ordering. Crated, it is a 479 lb pallet — a forklift or pallet-jack job, or a trailer at the freight terminal if you have neither. Drivers deliver to the tail of the truck, not into your building. Residential delivery is available and carries a fee, shown at checkout. When the truck arrives, inspect the crate with the driver and write any damage onto the bill of lading before you sign it; a clean signature closes off most of the argument.\u003c\/p\u003e\u003cp\u003eSchulz equipment can also be collected from Acworth, GA. Call, text or chat if you would like the supply voltage or the part number confirmed first: 866-774-7743.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cp\u003eCover is 1 year on the unit with 2 years on the pump. Keep proof of purchase and record the date it was put into service.\u003c\/p\u003e\u003cp\u003eOne rule that decides most warranty outcomes: do not dismantle the pump, motor or starter before the claim is opened. An opened machine is normally out of scope regardless of how correct the diagnosis turns out to be. Call us and we will raise it with Schulz.\u003c\/p\u003e","brand":"Schulz of America","offers":[{"title":"Default Title","offer_id":49287163150490,"sku":"932.9346-0-208","price":2298.8,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/coretarps.co.uk\/products\/schulz-v-series-5hp-air-compressor","provider":"My Store","version":"1.0","type":"link"}